Vacuum System Controller Failure
TASK 38-31-00-810-806-A
Vacuum System Controller Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-067-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-057-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-055-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:13 UTC
Vacuum System Controller Failure
1. Possible Causes
- CONTROLLER VACUUM SYS [31MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| ASM 383111 | |
| AMM 38-31-34-000-001 | Removal of the Vacuum System Controller |
| AMM 38-31-34-400-001 | Installation of the Vacuum System Controller |
Subtask 38-31-00-710-067-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-057-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-055-B ** ON A/C NOT FOR ALL
A. If the operational test does no operate:
VSC
POWER SUPPLY: or
VSC
ARINC TRANSMITTER: or
VSC
RAM: or
VSC
EPROM: or
VSC
EEPROM: or
VSC
A/D.D/A CONVERTER: or
VSC
WATCHDOG TIMER: or
VSC
FEEDBACK
FAULTY LAV X: or
VSC
FEEDBACK
SYSTEM INOPERATIVE: or
VSC
FEEDBACK
LIQUID LEVEL SENSOR
TEST: or
VSC
FEEDBACK
PRECHARGE INDICATION: or
VSC
FEEDBACK
FLUSH ENABLE LAV X: or
VSC
FEEDBACK
MOTOR STARTING RELAY:
Subtask 38-31-00-710-055-A ** ON A/C NOT FOR ALL - refer to the bite test last leg or previous legs report.
VSC
POWER SUPPLY: or
VSC
ARINC TRANSMITTER: or
VSC
RAM: or
VSC
EPROM: or
VSC
EEPROM: or
VSC
A/D.D/A CONVERTER: or
VSC
WATCHDOG TIMER: or
VSC
FEEDBACK
FAULTY LAV X: or
VSC
FEEDBACK
SYSTEM INOPERATIVE: or
VSC
FEEDBACK
LIQUID LEVEL SENSOR
TEST: or
VSC
FEEDBACK
PRECHARGE INDICATION: or
VSC
FEEDBACK
FLUSH ENABLE LAV X: or
VSC
FEEDBACK
MOTOR STARTING RELAY:
- replace the CONTROLLER VACUUM SYS [31MG] , AMM 38-31-34-000-001 and AMM 38-31-34-400-001.
- do a check and repair the aircraft wiring ASM 383111 as necessary.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation of the vacuum toilet system AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the test as given in paragraph 3. A. to check the correct operation of the vacuum toilet system AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display