Liquid Level Sensor Failure
TASK 38-31-00-810-805-A
Liquid Level Sensor Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-099-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-054-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-083-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:12 UTC
Liquid Level Sensor Failure
1. Possible Causes
- SENSOR,LEVEL [41MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-63-000-001 | Removal of the Liquid Level Sensor |
| AMM 38-31-63-400-001 | Installation of the Liquid Level Sensor |
Subtask 38-31-00-710-099-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-054-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-083-B ** ON A/C NOT FOR ALL
A. If the operational test is OK:
Subtask 38-31-00-710-066-A - Refer to the trouble shooting page of the bite test.
- do a check of the electrical connections of the connector (41MG).
- replace the SENSOR,LEVEL [41MG] , AMM 38-31-63-000-001 and AMM 38-31-63-400-001.
B. Test
(1) Do the operational test of the vacuum toilet system and make sure it operates correctly AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the operational test of the vacuum toilet system and make sure it operates correctly AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.