Liquid Level Transmitter Failure
TASK 38-31-00-810-804-A
Liquid Level Transmitter Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-053-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-053-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-082-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:12 UTC
Liquid Level Transmitter Failure
1. Possible Causes
- XMTR-LEVEL [40MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-62-000-001 | Removal of the Liquid Level Transmitter |
| AMM 38-31-62-400-001 | Installation of the Liquid Level Transmitter |
Subtask 38-31-00-710-053-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-053-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-082-B ** ON A/C NOT FOR ALL
A. If the operational test is OK:
(2) If the fault continues:
Subtask 38-31-00-710-065-A ** ON A/C NOT FOR ALL - Refer bite test last leg or previous legs report.
- do a check of the differential pressure line and the flexible hose P/N MTR1008-001 for possible damage. If necessary, replace the hose or line.
- If the fault continues:
(2) If the fault continues:
- do a check of the electrical connections of the small connector 40MG/A.
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
B. Test
(1) Do the operational test of the vacuum toilet system and make sure it operates correctly AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the operational test of the vacuum toilet system and make sure it operates correctly AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display