Vacuum Generator Failure


TASK 38-31-00-810-803-A
Vacuum Generator Failure


1. Possible Causes
  • GENERATOR,VACUUM [37MG]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-31-00-710-009
Operational Test of the Toilet Unit
AMM 38-31-00-740-001
BITE Test of the Vacuum Toilet System
AMM 38-31-64-000-001
Removal of the Vacuum Generator
AMM 38-31-64-400-001
Installation of the Vacuum Generator
F MCDU Display ** ON A/C NOT FOR ALL
3. Fault Confirmation
Subtask 38-31-00-740-052-A ** ON A/C NOT FOR ALL
A. Fault Confirmation Test
   (1) Do the operational test of the toilet unit AMM 38-31-00-710-009.
   (2) Do the bite test of the vacuum toilet system AMM 38-31-00-740-001.
4. Fault Isolation
Subtask 38-31-00-810-052-C ** ON A/C NOT FOR ALL
A. If the operational test is satisfactory:
  • Do the bite test to get the last leg report page.
    F MCDU Display ** ON A/C NOT FOR ALL
   (1) If the LAST LEG REPORT page gives the maintenance message VACU GEN:
  • do a check of the electrical connections 37MG/A and 37MG/B.
   (2) If the electrical connections are correct:
Subtask 38-31-00-710-052-A ** ON A/C NOT FOR ALL
B. Do the test as given in Para. 3.
   (1) Make sure that the vacuum toilet system operates correctly AMM 38-31-00-710-009.
   (2) After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:34:12 UTC