Vacuum Generator Failure
TASK 38-31-00-810-803-A
Vacuum Generator Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-740-052-A ** ON A/C NOT FOR ALL
Subtask 38-31-00-810-052-C ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:12 UTC
Vacuum Generator Failure
1. Possible Causes
- GENERATOR,VACUUM [37MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-64-000-001 | Removal of the Vacuum Generator |
| AMM 38-31-64-400-001 | Installation of the Vacuum Generator |
Subtask 38-31-00-740-052-A ** ON A/C NOT FOR ALL
A. Fault Confirmation Test
(1) Do the operational test of the toilet unit AMM 38-31-00-710-009.
(2) Do the bite test of the vacuum toilet system AMM 38-31-00-740-001.
4. Fault Isolation(1) Do the operational test of the toilet unit AMM 38-31-00-710-009.
(2) Do the bite test of the vacuum toilet system AMM 38-31-00-740-001.
Subtask 38-31-00-810-052-C ** ON A/C NOT FOR ALL
A. If the operational test is satisfactory:
Subtask 38-31-00-710-052-A ** ON A/C NOT FOR ALL - Do the bite test to get the last leg report page.
- do a check of the electrical connections 37MG/A and 37MG/B.
- replace the GENERATOR,VACUUM [37MG] AMM 38-31-64-000-001 and AMM 38-31-64-400-001.
B. Do the test as given in Para. 3.
(1) Make sure that the vacuum toilet system operates correctly AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Make sure that the vacuum toilet system operates correctly AMM 38-31-00-710-009.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display