Potable-Water Service Panel 2023VU Indication Light(s) Failure
TASK 38-13-00-810-803-A
Potable-Water Service Panel 2023VU Indication Light(s) Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-13-00-710-054-A
Subtask 38-13-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:12 UTC
Potable-Water Service Panel 2023VU Indication Light(s) Failure
1. Possible Causes
- lamp
- aircraft wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-13-00-960-001 | Indication Lamps Replacement |
| ASM 381301 |
Subtask 38-13-00-710-054-A
A. Do the self-test (push to test) of the indication lamp, the light must come ON.
4. Fault IsolationSubtask 38-13-00-810-054-A
A. If the light does not come ON:
Subtask 38-13-00-710-055-A - Replace the lamp AMM 38-13-00-960-001.
- Do a check and repair the aircraft wiring ASM 381301.
B. Do the test given in Para. 3.