Water Quantity Indication Failure


TASK 38-13-00-810-801-A
Water Quantity Indication Failure


1. Possible Causes
  • MSW-LIMIT SW [5MA]
  • INDICATOR,QUANTITY [6MA]
  • TRANSMITTER,QUANTITY [3MA]
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-13-00-710-001
Operational Test of the Quantity Indicating System
AMM 38-13-00-710-002
Operational Test of the Door Limit Switch
AMM 38-13-00-820-801
Adjustment of the Stud for Limit-Switch (5MA) of Potable-Water Service-Panel Access-Door (171AL)
ASM 381301
AMM 38-13-11-000-001
Removal of the Quantity Transmitter
AMM 38-13-11-400-001
Installation of the Quantity Transmitter
AMM 38-13-16-000-001
Removal of the Water Service-Panel Door-Switch
AMM 38-13-16-400-001
Installation of the Water Service-Panel Door-Switch
AMM 38-13-21-000-001
Removal of the Quantity Indicator
AMM 38-13-21-400-001
Installation of the Quantity Indicator
AMM 38-14-00-710-001
Operational Test of the Potable Water Drain-System
3. Fault Confirmation
Subtask 38-13-00-710-050-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do a test of the Quantity Indicating System AMM 38-13-00-710-001.
Subtask 38-13-00-710-050-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do a test of the Quantity Indication System AMM 38-13-00-710-001.
   (2) Do a test of the Water Draining (Dump) AMM 38-14-00-710-001.
4. Fault Isolation
Subtask 38-13-00-810-050-B
A. If there is no quantity indication (no LED illumination/quantity indicator) on the FORWARD ATTENDANT PANEL 120RH/SERVICE PANEL 2023VU:
  • open and close the circuit breaker 1MA.
   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
   (5) If the fault continues:
  • do a check and repair the aircraft wiring between the:
    CB 1MA and the connector A/C TRANSMITTER,QUANTITY [3MA] ASM 381301.
Subtask 38-13-00-710-051-A
B. Do the test as given in paragraph 3. A.