Water Leakage from Potable Water System
TASK 38-12-00-810-815-A
Water Leakage from Potable Water System
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-12-00-710-078-A
Subtask 38-12-00-810-065-A
Subtask 38-12-00-710-079-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:12 UTC
Water Leakage from Potable Water System
1. Possible Causes
- water filter
- connections
- lines
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-15-38-613-001 | Fill the Potable Water Tank System (Aircraft Electrical Power Available) |
| AMM 20-23-38-300-001 | Repair of the Tubes Assembly of the Potable Water and the associated Air Supply System to be carried out in the Workshop |
| AMM 20-23-38-300-002 | Repair of the Tubes of the Potable Water and the associated Air Supply System to be carried out in the Aircraft |
| AMM 20-23-38-300-048 | Repair of the Tubes with H-Fittings to be carried out in the Aircraft |
| AMM 20-23-38-300-049 | Temporary Repair of the Tube Assemblies with MS21922 Sleeves to be carried out in the Workshop |
| AMM 38-10-00-614-001 | Pressurization of the Potable Water System from a Ground Air Supply |
Subtask 38-12-00-710-078-A
A. Aircraft configuration
(1) Make sure that there is water in the potable water system, if necessary do the servicing AMM 12-15-38-613-001.
(2) Make sure that the potable water system is pressurized AMM 38-10-00-614-001.
4. Fault Isolation(1) Make sure that there is water in the potable water system, if necessary do the servicing AMM 12-15-38-613-001.
(2) Make sure that the potable water system is pressurized AMM 38-10-00-614-001.
Subtask 38-12-00-810-065-A
A. If you see a flow of water from the potable water system:
5. Close-up- do a check in the logbook to make sure if any work was performed on the system.
- The water filter does not leak.
- All connections , lines and plugs are tightened.
- The interface to all other users does not leak.
- Do a check and make sure that all connections and lines do not leak.
- Use the illustration to trace for possible leaks.
Subtask 38-12-00-710-079-A
A. After consequent maintenance or repair, pressurize the potable water system and make sure that the system does not leak.
Routing of Potable Water Lines