W DOC AIRBUS | TSM A320F

No Pressurization of the Potable Water in Flight


TASK 38-12-00-810-814-A
No Pressurization of the Potable Water in Flight


1. Possible Causes
  • VALVE-OVERFLOW [8MP]
  • Fill limit switch 5MP
  • control cable 3260MM
  • aircraft wiring
  • control cable 3261MM
  • control cable 3254MM
  • FILL/DRAIN VALVE [8MA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 12-15-38-613-001
Fill the Potable Water Tank System (Aircraft Electrical Power Available)
AMM 38-10-00-614-001
Pressurization of the Potable Water System from a Ground Air Supply
ASM 381300
ASM 381400
AMM 38-14-43-000-001
Removal of the Motorized Fill/Overflow-Drain Valve
AMM 38-14-43-400-001
Installation of the Motorized Fill/Overflow-Drain Valve
AMM 38-14-44-000-001
Removal of the Overflow Valve
AMM 38-14-44-400-001
Installation of the Overflow Valve
AMM 38-14-47-000-001
Removal of the Control Cable
AMM 38-14-47-400-001
Installation of the Control Cable
AMM 38-14-48-000-001
Removal of the Control Cable
AMM 38-14-48-400-001
Installation of the Control Cable
3. Fault Confirmation
Subtask 38-12-00-710-076-A
A. Aircraft configuration
   (1) Make sure that there is water in the potable water system, if necessary do the servicing AMM 12-15-38-613-001.
   (2) Make sure that the potable water system is pressurized AMM 38-10-00-614-001.
4. Fault Isolation
Subtask 38-12-00-810-063-A ** ON A/C NOT FOR ALL
A. If you cannot pressurize the potable water system:
  • do a check and make sure that no air flows from the VALVE-OVERFLOW [8MP] .
   (1) If the over-flow valve 8MP is not closed:
  • do a check and adjust the Fill limit switch 5MP as necessary.
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
  • do a check and repair the aircraft wiring between the:
    CB 1MP and the connector A/C VALVE-OVERFLOW [8MP] , ASM 381400.
   (5) If the fault continues:
   (6) If the fault continues:
Subtask 38-12-00-810-063-B ** ON A/C NOT FOR ALL
A. If you cannot pressurize the potable water system:
  • do a check and make sure that no air flows from the FILL/DRAIN VALVE [8MA] .
   (1) If the fill/drain and overflow valve 8MA is not closed:
  • do a check and adjust the control cable 3254MM as necessary.
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
  • do a check and repair the aircraft wiring between the:
    CB 1MA and the connector A/C FILL/DRAIN VALVE [8MA] , ASM 381300.
5. Close-up
Subtask 38-12-00-710-077-A
A. After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:34:12 UTC