No Pressurization of the Potable Water in Flight
TASK 38-12-00-810-814-A
No Pressurization of the Potable Water in Flight
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-12-00-710-076-A
Subtask 38-12-00-810-063-A ** ON A/C NOT FOR ALL
Subtask 38-12-00-710-077-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:12 UTC
No Pressurization of the Potable Water in Flight
1. Possible Causes
- VALVE-OVERFLOW [8MP]
- Fill limit switch 5MP
- control cable 3260MM
- aircraft wiring
- control cable 3261MM
- control cable 3254MM
- FILL/DRAIN VALVE [8MA]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-15-38-613-001 | Fill the Potable Water Tank System (Aircraft Electrical Power Available) |
| AMM 38-10-00-614-001 | Pressurization of the Potable Water System from a Ground Air Supply |
| ASM 381300 | |
| ASM 381400 | |
| AMM 38-14-43-000-001 | Removal of the Motorized Fill/Overflow-Drain Valve |
| AMM 38-14-43-400-001 | Installation of the Motorized Fill/Overflow-Drain Valve |
| AMM 38-14-44-000-001 | Removal of the Overflow Valve |
| AMM 38-14-44-400-001 | Installation of the Overflow Valve |
| AMM 38-14-47-000-001 | Removal of the Control Cable |
| AMM 38-14-47-400-001 | Installation of the Control Cable |
| AMM 38-14-48-000-001 | Removal of the Control Cable |
| AMM 38-14-48-400-001 | Installation of the Control Cable |
Subtask 38-12-00-710-076-A
A. Aircraft configuration
(1) Make sure that there is water in the potable water system, if necessary do the servicing AMM 12-15-38-613-001.
(2) Make sure that the potable water system is pressurized AMM 38-10-00-614-001.
4. Fault Isolation(1) Make sure that there is water in the potable water system, if necessary do the servicing AMM 12-15-38-613-001.
(2) Make sure that the potable water system is pressurized AMM 38-10-00-614-001.
Subtask 38-12-00-810-063-A ** ON A/C NOT FOR ALL
A. If you cannot pressurize the potable water system:
Subtask 38-12-00-810-063-B ** ON A/C NOT FOR ALL - do a check and make sure that no air flows from the VALVE-OVERFLOW [8MP] .
- do a check and adjust the Fill limit switch 5MP as necessary.
- do a check and make sure that the over-flow valve 8MP control cable 3260MM moves freely. If not, replace the control cable AMM 38-14-48-000-001 and AMM 38-14-48-400-001.
- replace the VALVE-OVERFLOW [8MP] , AMM 38-14-44-000-001 and AMM 38-14-44-400-001.
- do a check and repair the aircraft wiring between the:
CB 1MP and the connector A/C VALVE-OVERFLOW [8MP] , ASM 381400.
- do a check and make sure that the drain valve 14MP control cable 3261MM moves freely. If not, replace the control cable AMM 38-14-48-000-001 and AMM 38-14-48-400-001.
- do a check and make sure that the fill and drain valve 16MA control cable 3254MM moves freely. If not, replace the control cable AMM 38-14-47-000-001 and AMM 38-14-47-400-001.
A. If you cannot pressurize the potable water system:
5. Close-up- do a check and make sure that no air flows from the FILL/DRAIN VALVE [8MA] .
- do a check and adjust the control cable 3254MM as necessary.
- do a check and make sure that the fill/drain and overflow valve 8MA control cable 3254MM moves freely. If not, replace the control cable AMM 38-14-47-000-001 and AMM 38-14-47-400-001.
- replace the FILL/DRAIN VALVE [8MA] , AMM 38-14-43-000-001 and AMM 38-14-43-400-001.
- do a check and repair the aircraft wiring between the:
CB 1MA and the connector A/C FILL/DRAIN VALVE [8MA] , ASM 381300.
Subtask 38-12-00-710-077-A
A. After the subsequent flight, make sure that the fault does not continue.