W DOC AIRBUS | TSM A320F

Failure of the APU Bleed Check-Valve with APU Leak


TASK 36-22-00-810-931-A
Failure of the APU Bleed Check-Valve with APU Leak


1. Possible Causes
  • CHECK VALVE-APU BLEED [7260HM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 36-12-00-810-807-A
APU Leak
AMM 36-12-51-000-002
Removal of the APU Bleed Check-Valve
AMM 36-12-51-200-001
Remove and Check Auxiliary Power Unit Bleed Check-Valve for Condition
AMM 36-12-51-400-002
Installation of the APU Bleed Check-Valve
3. Fault Confirmation
Subtask 36-22-00-860-080-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On AIR control-panel 30VU:
     (a) Make sure that all the ENG BLEED pushbutton switches are pushed (OFF legends off).
Subtask 36-22-00-740-074-A ** ON A/C NOT FOR ALL
B. Test
   (1) Not Applicable
4. Fault Isolation
Subtask 36-22-00-810-231-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message:
APUCV 7260HA + APU LEAK:
   (1) Remove the APU bleed check valve AMM 36-12-51-000-002.
     (a) Do a check of the APU bleed check-valve AMM 36-12-51-200-001.
   (2) If you find damage:
   (3) If you do not find damage:
5. Close-up
Subtask 36-22-00-710-167-A ** ON A/C NOT FOR ALL
A. After the subsequent flight, make sure that the fault does not continue.