Air Leak in the Right Wing with the APU in Operation
TASK 36-22-00-810-883-A
Air Leak in the Right Wing with the APU in Operation
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-860-064-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-810-154-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-860-068-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:11 UTC
Air Leak in the Right Wing with the APU in Operation
1. Possible Causes
- ducts
- seals
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-52-00-200-010 | Hot-Air Leak-Check in the Air Conditioning Bay |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| AMM 36-11-48-000-004 | Removal of the Bleed Air Ducts |
| AMM 36-11-48-400-004 | Installation of the Bleed Air Ducts |
| AMM 36-22-00-790-802 | Leak Check on all the Bleed Air Ducts and Packs Components |
| AMM 49-00-00-860-008 | APU Start by External Power |
| AMM 49-00-00-860-009 | APU Shutdown by External Power (131-9(A)) |
Subtask 36-22-00-860-064-A ** ON A/C NOT FOR ALL
A. Job Set-up
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 36-22-00-860-067-B ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
(1) Start the APU AMM 49-00-00-860-008.
(2) On AIR COND panel 30VU, push the APU BLEED pushbutton switch (5HV) (the ON legend comes on).
4. Fault Isolation(1) Start the APU AMM 49-00-00-860-008.
(2) On AIR COND panel 30VU, push the APU BLEED pushbutton switch (5HV) (the ON legend comes on).
Subtask 36-22-00-810-154-A ** ON A/C NOT FOR ALL
A. On the upper ECAM DU, if the AIR R WING LEAK warning comes into view:
5. Close-up- do a leak test on the bleed air ducts between wing anti ice valves and wing fuselage connections AMM 36-22-00-790-802.
- replace the defective ducts or seals as necessary AMM 36-11-48-000-004 and AMM 36-11-48-400-004.
- do a hot-air leak check in the air conditioning bay AMM 21-52-00-200-010.
- replace the defective ducts AMM 36-11-48-000-004 and AMM 36-11-48-400-004.
- replace the defective seals .
Subtask 36-22-00-860-068-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the AIR COND panel 30VU, release the APU BLEED pushbutton switch (5HV) (the ON legend goes off).
(2) Stop the APU AMM 49-00-00-860-009.
Subtask 36-22-00-860-065-A ** ON A/C NOT FOR ALL (1) On the AIR COND panel 30VU, release the APU BLEED pushbutton switch (5HV) (the ON legend goes off).
(2) Stop the APU AMM 49-00-00-860-009.
B. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) Do the EIS stop procedure
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.