W DOC AIRBUS | TSM A320F

Leak Detection of the Engine 2 Pylon Loop A


TASK 36-22-00-810-881-A
Leak Detection of the Engine 2 Pylon Loop A


1. Possible Causes
  • BMC-1 [1HA1]
  • CABLE-CONNECTING, ENG 2 PYLON [2HF2]
  • wiring
  • SNSG ELEM-OVHT, ENG 2 PYLON [1HF2]
  • SENSING ELEMENT-OVHT, R PYLON LOOP A [6HF2]
  • CABLE-CONNECTING, R PYLON LOOP A [4HF2]
  • CABLE-CONNECTING, R PYLON LOOP A [5HF2]
  • CABLE ASSY [3HF2]
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
9240SI
1
CONTROLLER-LOOP
 B. Referenced Information
REFERENCE
DESIGNATION
ESPM 204422
AMM 36-11-00-740-802
BITE Test of the Engine Bleed Air System (EBAS) (System Test)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
ASM 362201
AMM 36-22-15-000-802
Removal of the Pylon Overheat Sensing-Elements
AMM 36-22-15-000-803
Removal of the Pylon Overheat Sensing-Elements
AMM 36-22-15-400-802
Installation of the Pylon Overheat Sensing-Elements
AMM 36-22-15-400-803
Installation of the Pylon Overheat Sensing-Elements
3. Fault Confirmation
Subtask 36-22-00-710-133-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the EBAS AMM 36-11-00-740-802.
4. Fault Isolation
Subtask 36-22-00-810-152-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
ENG2 PYLON LOOP A()
  • Remove BMC1 (1HA1) AMM 36-11-34-000-001.
  • On the shelf 95VU, connect the 9240SI CONTROLLER-LOOP between connector 1HA1-AA/4D and the ground ASM 362201.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
   (1) If the impedance is more than 10 kOhms:
   (2) If the impedance is less than 10 kOhms:
  • Do a visual inspection of the sensing elements and cables on the engine 2 pylon loop A.
     (a) If a sensing element or cable is damaged:
     (b) If no sensing element is damaged:
  • Disconnect the connector between cable 2HF2 and sensing element 1HF2.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
       1 If the impedance is less than 10 kOhms:
  • Replace the CABLE-CONNECTING, ENG 2 PYLON [2HF2] ESPM 204422.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 10 kOhms:
  • Do a check and repair the wiring between pin AA/4D of BMC1 (1HA1) and cable 2HF2 ASM 362201.
  • Connect all the cables or connectors disconnected.
  • Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
  • Install BMC1 (1HA1) AMM 36-11-34-400-001.
  • Refer to Para. 4.B.
         b If the impedance is more than 10 kOhms:
  • Connect all the cables or connectors disconnected.
  • Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
  • Install BMC1 (1HA1) AMM 36-11-34-400-001.
  • Refer to Para. 4.B.
       2 If the impedance is more than 10 kOhms:
  • Disconnect the connector between cable 3HF2 and sensing element 6HF2.
  • Connect the connector between cable 2HF2 and sensing element 1HF2.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 10 kOhms:
  • Disconnect the connector between cable 4HF2 and sensing element 1HF2.
  • Connect the connector between cable 3HF2 and sensing element 6HF2.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 17 kOhms:
    - Replace the SNSG ELEM-OVHT, ENG 2 PYLON [1HF2] AMM 36-22-15-000-803 and AMM 36-22-15-400-803.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install BMC-1 [1HA1] AMM 36-11-34-400-001.
    - Refer to Para. 4.B.

    * If the impedance is more than 17 kOhms:
    - Disconnect the connector between cable 5HF2 and sensing element 6HF2.
    - Connect the connector between cable 4HF2 and sensing element 1HF2.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is more than 10 kOhms:
    - Replace the SENSING ELEMENT-OVHT, R PYLON LOOP A [6HF2] AMM 36-22-15-000-802 and AMM 36-22-15-400-802.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install BMC-1 [1HA1] AMM 36-11-34-400-001.
    - Refer to Para. 4.B.

    ** If the impedance is less than 10 kOhms:
    - Replace the CABLE-CONNECTING, R PYLON LOOP A [4HF2] and CABLE-CONNECTING, R PYLON LOOP A [5HF2] ESPM 204422.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install BMC-1 [1HA1] AMM 36-11-34-400-001.
    - Refer to Para. 4.B.
         b If the impedance is more than 10 kOhms:
  • Replace the CABLE ASSY [3HF2] ESPM 204422.
  • Connect all the cables or connectors disconnected.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 kOhms:
    - Do a check and repair the wiring between pin AA/5D of BMC1 (1HA1) and cable 3HF2 ASM 362201.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.B.

    * If the impedance is more than 10 kOhms:
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.B.
Subtask 36-22-00-710-134-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:30 UTC