Leak Detection of the Engine 1 Pylon Loop A
TASK 36-22-00-810-880-A
Leak Detection of the Engine 1 Pylon Loop A
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-131-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-151-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:10 UTC
Leak Detection of the Engine 1 Pylon Loop A
1. Possible Causes
- BMC-1 [1HA1]
- CABLE-CONNECTING, ENG 1 PYLON [2HF1]
- wiring
- SNSG ELEM-OVHT, ENG 1 PYLON [1HF1]
- SENSING ELEMENT-OVHT, L PYLON LOOP A [6HF1]
- CABLE-CONNECTING, L PYLON LOOP A [4HF1]
- CABLE-CONNECTING, L PYLON LOOP A [5HF1]
- CABLE ASSY [3HF1]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 9240SI | 1 | CONTROLLER-LOOP |
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 204422 | |
| AMM 36-11-00-740-802 | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| ASM 362201 | |
| AMM 36-22-15-000-802 | Removal of the Pylon Overheat Sensing-Elements |
| AMM 36-22-15-000-803 | Removal of the Pylon Overheat Sensing-Elements |
| AMM 36-22-15-400-802 | Installation of the Pylon Overheat Sensing-Elements |
| AMM 36-22-15-400-803 | Installation of the Pylon Overheat Sensing-Elements |
Subtask 36-22-00-710-131-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-151-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
ENG1 PYLON LOOP A()
Subtask 36-22-00-710-132-A ** ON A/C NOT FOR ALL ENG1 PYLON LOOP A()
- Remove BMC1 (1HA1) AMM 36-11-34-000-001.
- On shelf 95VU, connect the 9240SI CONTROLLER-LOOP between connector 1HA1-AA/4E and the ground ASM 362201.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Replace BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- Refer to Para. 4.B.
- Do a visual inspection of the sensing elements and cables on engine 1 pylon loop A.
- Replace the sensing element or cable AMM 36-22-15-000-802 and AMM 36-22-15-400-802.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install BMC1 AMM 36-11-34-400-001.
- Refer to Para. 4.B.
- Disconnect the connector between cable 2HF1 and sensing element 1HF1.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- Replace the CABLE-CONNECTING, ENG 1 PYLON [2HF1] ESPM 204422.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- Do a check and repair the wiring between pin AA/4E of BMC1 (1HA1) and cable 2HF1 ASM 362201.
- Connect all the cables or connectors disconnected.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.B.
- Connect all the cables or connectors disconnected.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.B.
- Disconnect the connector between cable 3HF1 and sensing element 6HF1.
- Connect the connector between cable 2HF1 and sensing element 1HF1.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- Disconnect the connector between cable 4HF1 and sensing element 1HF1.
- Connect the connector between cable 3HF1 and sensing element 6HF1.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
* If the impedance is less than 17 kOhms:
- Replace the SNSG ELEM-OVHT, ENG 1 PYLON [1HF1] AMM 36-22-15-000-803 and AMM 36-22-15-400-803.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC connector.
- Install BMC-1 [1HA1] which is removed AMM 36-11-34-400-001.
- Refer to Para. 4.B.
* If the impedance is more than 17 kOhms:
- Disconnect the connector between cable 5HF1 and sensing element 6HF1.
- Connect the connector between cable 4HF1 and sensing element 1HF1.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
** If the impedance is more than 10 kOhms:
- Replace the SENSING ELEMENT-OVHT, L PYLON LOOP A [6HF1] AMM 36-22-15-000-802 and AMM 36-22-15-400-802.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC connector.
- Install BMC-1 [1HA1] AMM 36-11-34-400-001.
- Refer to Para. 4.B.
** If the impedance is less than 10 kOhms:
- Replace the CABLE-CONNECTING, L PYLON LOOP A [4HF1] and CABLE-CONNECTING, L PYLON LOOP A [5HF1] ESPM 204422.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC connector.
- Install BMC-1 [1HA1] AMM 36-11-34-400-001.
- Refer to Para. 4.B.
- Replace the CABLE ASSY [3HF1] ESPM 204422.
- Connect all the cables or connectors disconnected.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
* If the impedance is less than 10 kOhms:
- Do a check and repair the wiring between pin AA/5E of BMC1 (1HA1) and cable 3HF1 ASM 362201.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.B.
* If the impedance is more than 10 kOhms:
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.B.
B. Do the test given in Para. 3.