Unwanted APU Leak Detection
TASK 36-22-00-810-850-A
Unwanted APU Leak Detection
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-096-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-810-114-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:08 UTC
Unwanted APU Leak Detection
1. Possible Causes
- BMC-1 [1HA1]
- sensing element
- cable
- SENSING ELEMENT-OVERHEAT,WING [11HF]
- wiring
- OVHT SENS ELEMENT [12HF]
- OVHT SENS ELEMENT [13HF]
- OVHT SENS ELEMENT [14HF]
- OVHT SENS ELEMENT [15HF]
- OVHT SENS ELEMENT [16HF]
- OVHT SENS ELEMENT [17HF]
- OVHT SENS ELEMENT [18HF]
- OVHT SENS ELEMENT [19HF]
- CABLE ASSY [20HF]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 9240SI | 1 | CONTROLLER-LOOP |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| ASM 362201 | |
| AMM 36-22-17-000-001 | Removal of the APU Overheat Sensing-Elements |
| AMM 36-22-17-400-001 | Installation of the APU Overheat Sensing-Elements |
Subtask 36-22-00-710-096-A ** ON A/C NOT FOR ALL
A. Test
(1) Not Applicable
4. Fault Isolation(1) Not Applicable
Subtask 36-22-00-810-114-A ** ON A/C NOT FOR ALL
A. If there is the ECAM warning AIR APU BLEED LEAK and the FAULT legend is ON on the APU BLEED pushbutton switch:
(1) Release and push the APU BLEED pushbutton switch to clean the warnings.
(a) If the warning goes out of view:
2 On shelf 95VU, connect a 9240SI CONTROLLER-LOOP between BMC1 (1HA1) pin AA/4C and the ground ASM 362201.
Subtask 36-22-00-710-097-A ** ON A/C NOT FOR ALL (1) Release and push the APU BLEED pushbutton switch to clean the warnings.
(a) If the warning goes out of view:
- No maintenance procedure is necessary.
- Do the impedance check of the APU overheat detection loop.
2 On shelf 95VU, connect a 9240SI CONTROLLER-LOOP between BMC1 (1HA1) pin AA/4C and the ground ASM 362201.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Replace the BMC-1 [1HA1] which is removed AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Do a visual inspection of the sensing elements and the cables on the APU loop.
- Replace the sensing element or the cable AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Disconnect the connector between sensing elements 15HF and 16HF.
- Connect the 9240SI CONTROLLER-LOOP between BMC1 (1HA1) pin AA/4C and the ground.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Disconnect the connector between sensing elements 13HF and 14HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Disconnect the connector between cable 11HF and sensing element 12HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Replace the SENSING ELEMENT-OVERHEAT,WING [11HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
* If the impedance is less than 10 KOhms:
** Do a check and repair the wiring between BMC1 (1HF1) pin AA/4C and cable 11HF.
** Connect all the cables or disconnected connectors.
** Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
* If the impedance is more than 10 KOhms:
- Connect all the cables or disconnected connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Disconnect the connector between sensing elements 12HF and 13HF.
- Connect the connector between cable 11HF and sensing element 12HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
* If the impedance is less than 500 KOhms:
** Replace the OVHT SENS ELEMENT [12HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
** Connect all the cables or disconnected connectors .
** Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
** Install the BMC1 (1HA1) AMM 36-11-34-400-001.
** Go to Para. 4.B.
* If the impedance is more than 500 KOhms:
** Replace the OVHT SENS ELEMENT [13HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
** Connect all the cables or disconnected connectors.
** Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
** Install the BMC1 (1HA1) AMM 36-11-34-400-001.
** Go to Para. 4.B.
- Connect the connector between sensing elements 13HF and 14HF.
- Disconnect the connector between sensing elements 14HF and 15HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Replace the OVHT SENS ELEMENT [14HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Connect all the cables or disconnected connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Replace the OVHT SENS ELEMENT [15HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Connect all the cables or disconnected connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Connect the connector between sensing elements 15HF and 16HF.
- Disconnect the connector between sensing elements 17HF and 18HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Disconnect the connector between sensing elements 16HF and 17HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Replace the OVHT SENS ELEMENT [16HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Connect all the cables or disconnected connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Replace the OVHT SENS ELEMENT [17HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Connect all the cables or disconnected connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Connect the connector between sensing elements 17HF and 18HF.
- Disconnect the connector between sensing element 19HF and cable 20HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- Disconnect the connector between sensing elements 18HF and 19HF.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
* If the impedance is less than 10 KOhms:
** Replace the OVHT SENS ELEMENT [18HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001
** Connect all the cables or disconnected connectors.
** Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
** Install the BMC1 (1HA1) AMM 36-11-34-400-001.
** Go to Para. 4.B.
* If the impedance is more than 10 KOhms:
** Replace the OVHT SENS ELEMENT [19HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
** Connect all the cables or disconnected connectors.
** Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
** Install the BMC1 (1HA1) AMM 36-11-34-400-001.
** Go to Para. 4.B.
- Replace the CABLE ASSY [20HF] AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Connect all the cables or disconnected connectors.
- Do an impedance check on the 9240SI CONTROLLER-LOOP.
- If the impedance is less than 10 KOhms:
* Do a check and repair the wiring between BMC1 (1HA1) pin AA/4C and cable 20HF.
* Connect all the cables or disconnected connector.
* Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
* Install the BMC1 (1HA1) AMM 36-11-34-400-001.
* Go to Para. 4.B.
- If the impedance is more than 10 KOhms:
* Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 (1HA1) connector.
* Install the BMC1 (1HA1) AMM 36-11-34-400-001.
* Go to Para. 4.B.
B. After the subsequent flight, make sure that the fault does not continue.