RH Wing Loop B Inoperative
TASK 36-22-00-810-839-A
RH Wing Loop B Inoperative
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-740-054-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-096-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:07 UTC
RH Wing Loop B Inoperative
1. Possible Causes
- wiring
- BMC-2 [1HA2]
- CABLE ASSY [76HF]
- OVHT SENS ELEMENT [75HF]
- OVHT SENS ELEMENT [79HF]
- INTERCONNECTING CABLE [93HF]
- SNSG ELEM-OVHT, R WING LOOP B [72HF]
- SNSG ELEM-OVHT, R WING LOOP B [71HF]
- SNSG ELEM-OVHT, R WING LOOP B [70HF]
- SNSG ELEM-OVHT, R WING LOOP B [69HF]
- CABLE-CONNECTING, R WING LOOP B [68HF]
- CABLE-CONNECTING, R WING LOOP B [67HF]
- SNSG ELEM-OVHT, R WING LOOP B [66HF]
- SNSG ELEM-OVHT, R WING LOOP B [65HF]
- SNSG ELEM-OVHT, R WING LOOP B [82HF]
- CABLE-CONNECTING, R WING LOOP B [64HF]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 9240SI | 1 | CONTROLLER-LOOP |
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-22-00-810-878-A | Leak Detection from the Loop B in the Right Wing |
| ESPM 204422 | |
| AMM 36-11-00-740-802 | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-22-00-100-803 | Clean the Overheat Detection System (OHDS) Connectors and Apply the Electrical Insulating Compound |
| ASM 362201 | |
| AWM 362202 | |
| AMM 36-22-16-000-001 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-002 | Removal of the Cables |
| AMM 36-22-16-000-003 | Removal of the Cables |
| AMM 36-22-16-000-004 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-005 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-006 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-007 | Removal of the Cables |
| AMM 36-22-16-400-001 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-002 | Installation of the Cables |
| AMM 36-22-16-400-003 | Installation of the Cables |
| AMM 36-22-16-400-004 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-005 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-007 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-008 | Installation of the Cables |
Subtask 36-22-00-740-054-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-096-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message R WING LOOP B INOP or R WING LOOP B OPEN:
Subtask 36-22-00-810-208-A ** ON A/C NOT FOR ALL NOTE: This procedure is applicable when there is a loss of the RH wing loop-B detection-signal or to the incorrect continuity of the loop.
- Remove BMC-2 AMM 36-11-34-000-001.
- On shelf 96VU, connect the 9240SI CONTROLLER-LOOP between BMC-2 pin AA/4F and AA/5F ASM 362201.
- Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
- On shelf 96VU, connect the 9240SI CONTROLLER-LOOP between connector BMC-2 pin AA/4F and the ground ASM 362201.
- Do a check of the insulation resistance shown on the 9240SI CONTROLLER-LOOP.
- Go to Para. 4.B.
- Do the fault isolation steps (Ref. TSM TASK 36-22-00-810-878).
- Connect the 9240SI CONTROLLER-LOOP between connector 1968VC pin A/20 to connector 1900VC pin A/28 AWM 362202.
- Do a visual inspection of the sensing elements and the connecting cables on RH wing loop B.
- Disconnect the 9240SI CONTROLLER-LOOP from connector 1968VC pin A/20 to connector 1900VC pin A/28.
- Replace the defective sensing element or connecting cable
AMM 36-22-16-000-001 and AMM 36-22-16-400-001,
AMM 36-22-16-000-002 and AMM 36-22-16-400-002,
AMM 36-22-16-000-003 and AMM 36-22-16-400-003,
AMM 36-22-16-000-007 and AMM 36-22-16-400-008,
AMM 36-22-16-000-004 and AMM 36-22-16-400-004,
AMM 36-22-16-000-005 and AMM 36-22-16-400-005 and
AMM 36-22-16-000-006 and AMM 36-22-16-400-007. - Install BMC-2 AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Connect the 9240SI CONTROLLER-LOOP between connector 1968VC pin A/20 and BMC-2 pin AA/4F AWM 362202.
- Disconnect the 9240SI CONTROLLER-LOOP from connector 1968VC pin A/20 and BMC-2 pin AA/4F.
- Repair or replace the wiring ESPM 204422.
- Install BMC-2 AMM 36-11-34-400-001.
- Connect the 9240SI CONTROLLER-LOOP between connector 1900VC pin A/28 and BMC-2 pin AA/5F AWM 362202.
- Repair or replace the wiring ESPM 204422.
- Install BMC-2 AMM 36-11-34-400-001.
- Do the cleaning procedure AMM 36-22-00-100-803.
- Do the BITE test of the EBAS AMM 36-11-00-740-802.
* If the fault continues:
** Replace BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
B. Dichotomy Procedure
(1) Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
(a) If the continuity resistance value is more than 16.5 Ohms:
NOTE: The purpose of this procedure is to find and isolate the elements that causes a high continuity resistance on loop-B of the RH wing.
(1) Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
(a) If the continuity resistance value is more than 16.5 Ohms:
- Disconnect the connecting cable (76HF) of connector 1968VC pin A/20 and the connecting cable (64HF) of the connector 1900VC pin A/28 AMM 36-22-16-000-002. Disconnect one after the other all the sensing elements between the connection cables (76HF) and (64HF) AMM 36-22-16-000-001, AMM 36-22-16-000-003, AMM 36-22-16-000-007, AMM 36-22-16-000-004, AMM 36-22-16-000-005 and AMM 36-22-16-000-006.
- Measure the continuity resistance with the 9240SI CONTROLLER-LOOP between the center pin on the two ends of each of the elements.
- Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
- Disconnect the 9240SI CONTROLLER-LOOP.
- Replace the defective elements:
CABLE ASSY [76HF] or
OVHT SENS ELEMENT [75HF] or
OVHT SENS ELEMENT [79HF] or
INTERCONNECTING CABLE [93HF] or
SNSG ELEM-OVHT, R WING LOOP B [72HF] or
SNSG ELEM-OVHT, R WING LOOP B [71HF] or
SNSG ELEM-OVHT, R WING LOOP B [70HF] or
SNSG ELEM-OVHT, R WING LOOP B [69HF] or
CABLE-CONNECTING, R WING LOOP B [68HF] or
CABLE-CONNECTING, R WING LOOP B [67HF] or
SNSG ELEM-OVHT, R WING LOOP B [66HF] or
SNSG ELEM-OVHT, R WING LOOP B [65HF] or
SNSG ELEM-OVHT, R WING LOOP B [82HF] or
CABLE-CONNECTING, R WING LOOP B [64HF]
AMM 36-22-16-000-001 and AMM 36-22-16-400-001,
AMM 36-22-16-000-002 and AMM 36-22-16-400-002,
AMM 36-22-16-000-003 and AMM 36-22-16-400-003,
AMM 36-22-16-000-007 and AMM 36-22-16-400-008,
AMM 36-22-16-000-004 and AMM 36-22-16-400-004,
AMM 36-22-16-000-005 and AMM 36-22-16-400-005 and
AMM 36-22-16-000-006 and AMM 36-22-16-400-007. - Install BMC-2 AMM 36-11-34-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP.
- Clean all the connections of the sensing elements and the connecting cables to remove contamination and decrease the resistance of the loop AMM 36-22-00-100-803 AWM 362202.
- Connect again all the sensing elements or connecting cables disconnected AMM 36-22-16-400-001, AMM 36-22-16-400-002, AMM 36-22-16-400-003, AMM 36-22-16-400-008, AMM 36-22-16-400-004, AMM 36-22-16-400-005 and AMM 36-22-16-400-007.
- Install BMC-2 AMM 36-11-34-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP.
- Connect again all the sensing elements or connecting cables disconnected AMM 36-22-16-400-001, AMM 36-22-16-400-002, AMM 36-22-16-400-003, AMM 36-22-16-400-008, AMM 36-22-16-400-004, AMM 36-22-16-400-005 and AMM 36-22-16-400-007.
- Replace BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.