RH Wing Loop A Inoperative
TASK 36-22-00-810-838-A
RH Wing Loop A Inoperative
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-740-053-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-095-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:33 UTC
RH Wing Loop A Inoperative
1. Possible Causes
- wiring
- BMC-1 [1HA1]
- CABLE-CONNECTING, R WING LOOP A [37HF]
- SNSG ELEM-OVHT, R WING LOOP A [80HF]
- SNSG ELEM-OVHT, R WING LOOP A [38HF]
- SNSG ELEM-OVHT, R WING LOOP A [39HF]
- CABLE-CONNECTING, R WING LOOP A [40HF]
- CABLE-CONNECTING, R WING LOOP A [41HF]
- SNSG ELEM-OVHT, R WING LOOP A [42HF]
- SNSG ELEM-OVHT, R WING LOOP A [43HF]
- SNSG ELEM-OVHT, R WING LOOP A [44HF]
- SNSG ELEM-OVHT, R WING LOOP A [45HF]
- INTERCONNECTING CABLE [92HF]
- OVHT SENS ELEMENT [74HF]
- ELEMENT-OVERHEAT SENSING [47HF]
- CABLE ASSY [48HF]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 9240SI | 1 | CONTROLLER-LOOP |
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-22-00-810-877-A | Leak Detection from the Loop A in the Right Wing |
| ESPM 204422 | |
| AMM 36-11-00-740-802 | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-22-00-100-803 | Clean the Overheat Detection System (OHDS) Connectors and Apply the Electrical Insulating Compound |
| ASM 362201 | |
| AWM 362201 | |
| AMM 36-22-16-000-001 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-002 | Removal of the Cables |
| AMM 36-22-16-000-003 | Removal of the Cables |
| AMM 36-22-16-000-004 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-005 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-006 | Removal of the Overheat Sensing Elements |
| AMM 36-22-16-000-007 | Removal of the Cables |
| AMM 36-22-16-400-001 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-002 | Installation of the Cables |
| AMM 36-22-16-400-003 | Installation of the Cables |
| AMM 36-22-16-400-004 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-005 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-007 | Installation of the Overheat Sensing Elements |
| AMM 36-22-16-400-008 | Installation of the Cables |
Subtask 36-22-00-740-053-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-095-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message R WING LOOP A INOP or R WING LOOP A OPEN:
Subtask 36-22-00-810-207-A ** ON A/C NOT FOR ALL NOTE: This procedure is applicable when there is a loss of the RH wing loop-A detection-signal or to the incorrect continuity of the loop.
- Remove BMC-1 AMM 36-11-34-000-001.
- On shelf 95VU, connect the 9240SI CONTROLLER-LOOP between BMC-1 pin AA/4F and AA/5F ASM 362201.
- Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
- On shelf 95VU, connect the 9240SI CONTROLLER-LOOP between connector BMC-1 pin AA/4F and the ground ASM 362201.
- Do a check of the insulation resistance shown on the 9240SI CONTROLLER-LOOP.
- Go to Para. 4.B.
- Do the fault isolation steps (Ref. TSM TASK 36-22-00-810-877).
- Connect the 9240SI CONTROLLER-LOOP between connector 1910VC pin A/15 to connector 1969VC pin A/21 AWM 362201.
- Do a visual inspection of the sensing elements and the connecting cables on RH wing loop A.
- Disconnect the 9240SI CONTROLLER-LOOP from connector 1910VC pin A/15 to connector 1969VC pin A/21.
- Replace the defective sensing element or connecting cable
AMM 36-22-16-000-001 and AMM 36-22-16-400-001,
AMM 36-22-16-000-002 and AMM 36-22-16-400-002,
AMM 36-22-16-000-003 and AMM 36-22-16-400-003,
AMM 36-22-16-000-007 and AMM 36-22-16-400-008,
AMM 36-22-16-000-004 and AMM 36-22-16-400-004,
AMM 36-22-16-000-005 and AMM 36-22-16-400-005 and
AMM 36-22-16-000-006 and AMM 36-22-16-400-007. - Install BMC-1 AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Connect the 9240SI CONTROLLER-LOOP between connector 1910VC pin A/15 and BMC-1 pin AA/4F AWM 362201.
- Disconnect the 9240SI CONTROLLER-LOOP from connector 1910VC pin A/15 and BMC-1 pin AA/4F.
- Repair or replace the wiring ESPM 204422.
- Install BMC-1 AMM 36-11-34-400-001.
- Connect the 9240SI CONTROLLER-LOOP between connector 1969VC pin A/21 and BMC-1 pin AA/5F AWM 362201.
- Repair or replace the wiring ESPM 204422.
- Install BMC-1 AMM 36-11-34-400-001.
- Do the cleaning procedure AMM 36-22-00-100-803.
- Do the BITE test of the EBAS AMM 36-11-00-740-802.
* If the fault continues:
** Replace BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
B. Dichotomy Procedure
(1) Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
(a) If the continuity resistance value is more than 16.5 Ohms:
NOTE: The purpose of this procedure is to find and isolate the elements that causes a high continuity resistance on loop-A of the RH wing.
(1) Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
(a) If the continuity resistance value is more than 16.5 Ohms:
- Disconnect the connecting cable (37HF) of connector 1910VC pin A/15 and the connecting cable (48HF) of the connector 1969VC pin A/21 AMM 36-22-16-000-002. Disconnect one after the other all the sensing elements between the connection cables (37HF) and (48HF) AMM 36-22-16-000-001, AMM 36-22-16-000-003, AMM 36-22-16-000-007, AMM 36-22-16-000-004, AMM 36-22-16-000-005 and AMM 36-22-16-000-006.
- Measure the continuity resistance with the 9240SI CONTROLLER-LOOP between the center pin on the two ends of each of the elements.
- Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
- Disconnect the 9240SI CONTROLLER-LOOP.
- Replace the defective elements:
CABLE-CONNECTING, R WING LOOP A [37HF] or
SNSG ELEM-OVHT, R WING LOOP A [80HF] or
SNSG ELEM-OVHT, R WING LOOP A [38HF] or
SNSG ELEM-OVHT, R WING LOOP A [39HF] or
CABLE-CONNECTING, R WING LOOP A [40HF] or
CABLE-CONNECTING, R WING LOOP A [41HF] or
SNSG ELEM-OVHT, R WING LOOP A [42HF] or
SNSG ELEM-OVHT, R WING LOOP A [43HF] or
SNSG ELEM-OVHT, R WING LOOP A [44HF] or
SNSG ELEM-OVHT, R WING LOOP A [45HF] or
INTERCONNECTING CABLE [92HF] or
OVHT SENS ELEMENT [74HF] or
ELEMENT-OVERHEAT SENSING [47HF] or
CABLE ASSY [48HF]
AMM 36-22-16-000-001 and AMM 36-22-16-400-001,
AMM 36-22-16-000-002 and AMM 36-22-16-400-002,
AMM 36-22-16-000-003 and AMM 36-22-16-400-003,
AMM 36-22-16-000-007 and AMM 36-22-16-400-008,
AMM 36-22-16-000-004 and AMM 36-22-16-400-004,
AMM 36-22-16-000-005 and AMM 36-22-16-400-005 and
AMM 36-22-16-000-006 and AMM 36-22-16-400-007. - Install BMC-1 AMM 36-11-34-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP.
- Clean all the connections of the sensing elements and the connecting cables to remove contamination and decrease the resistance of the loop AMM 36-22-00-100-803 AWM 362201.
- Connect again all the sensing elements or connecting cables disconnected AMM 36-22-16-400-001, AMM 36-22-16-400-002, AMM 36-22-16-400-003, AMM 36-22-16-400-008, AMM 36-22-16-400-004, AMM 36-22-16-400-005 and AMM 36-22-16-400-007.
- Install BMC-1 AMM 36-11-34-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP.
- Connect again all the sensing elements or connecting cables disconnected AMM 36-22-16-400-001, AMM 36-22-16-400-002, AMM 36-22-16-400-003, AMM 36-22-16-400-008, AMM 36-22-16-400-004, AMM 36-22-16-400-005 and AMM 36-22-16-400-007.
- Replace BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.