Air Leak in the Left Wing with the APU in Operation
TASK 36-22-00-810-832-A
Air Leak in the Left Wing with the APU in Operation
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-860-050-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-810-090-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-860-051-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:06 UTC
Air Leak in the Left Wing with the APU in Operation
1. Possible Causes
- ducts
- seals
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-52-00-200-010 | Hot-Air Leak-Check in the Air Conditioning Bay |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| AMM 36-22-00-790-001 | Leak Check on all the Bleed Air Ducts and Packs Components |
| AMM 49-00-00-860-003 | APU Start by External Power |
| AMM 49-00-00-860-004 | APU Shutdown by External Power |
| AMM 49-00-00-860-005 | APU Start by External Power |
| AMM 49-00-00-860-006 | APU Shutdown by External Power |
| AMM 49-00-00-860-008 | APU Start by External Power |
| AMM 49-00-00-860-009 | APU Shutdown by External Power (131-9(A)) |
Subtask 36-22-00-860-050-A ** ON A/C NOT FOR ALL
A. Job Set-up
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 36-22-00-710-092-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
(1) Start the APU:
4. Fault Isolation(1) Start the APU:
- GTCP 36-300 AMM 49-00-00-860-003
or - APS 3200 AMM 49-00-00-860-005
or - 131-9(A) AMM 49-00-00-860-008.
Subtask 36-22-00-810-090-A ** ON A/C NOT FOR ALL
A. On the upper ECAM DU, if the AIR L WING LEAK warning comes into view:
5. Close-up- do a leak test on the bleed air ducts AMM 36-22-00-790-001.
- replace the defective ducts or seals as necessary.
- do a hot-air leak check in the air conditioning bay AMM 21-52-00-200-010.
- replace the defective ducts .
- replace the defective seals .
Subtask 36-22-00-860-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the AIR COND panel 30VU, release the APU BLEED pushbutton switch (5HV) (the ON legend goes off).
(2) Stop the APU:
AMM 31-60-00-860-002.
(4) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) On the AIR COND panel 30VU, release the APU BLEED pushbutton switch (5HV) (the ON legend goes off).
(2) Stop the APU:
- GTCP 36-300 AMM 49-00-00-860-004
or - APS 3200 AMM 49-00-00-860-006
or - 131-9(A) AMM 49-00-00-860-009.
AMM 31-60-00-860-002.
(4) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.