Leak Detection on the Engine 2 Pylon
TASK 36-22-00-810-831-A
Leak Detection on the Engine 2 Pylon
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-087-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-081-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:06 UTC
Leak Detection on the Engine 2 Pylon
1. Possible Causes
- BMC-2 [1HA2]
- CABLE-CONNECTING, ENG 2 PYLON [2HF2]
- wiring
- SNSG ELEM-OVHT, ENG 2 PYLON [1HF2]
- CABLE ASSY [3HF2]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 9240SI | 1 | CONTROLLER-LOOP |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| ASM 362201 | |
| AMM 36-22-15-000-001 | Removal of the Pylon Overheat Sensing-Element |
| AMM 36-22-15-400-001 | Installation of the Pylon Overheat Sensing-Element |
Subtask 36-22-00-710-087-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-081-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
ENG2 PYLON LOOP
Subtask 36-22-00-710-088-A ** ON A/C NOT FOR ALL ENG2 PYLON LOOP
- remove the BMC2 (1HA2) AMM 36-11-34-000-001
- on the shelf 96VU, connect the 9240SI CONTROLLER-LOOP between the connector 1HA2-AA/6B and the ground ASM 362201
- do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- replace the BMC-2 [1HA2] which is removed AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- refer to Para. 4.B.
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- do a visual inspection of the sensing elements and cables on the engine 2 pylon loop.
- replace the sensing element or cable AMM 36-22-15-000-001 and AMM 36-22-15-400-001
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- install the BMC2 AMM 36-11-34-400-001
- refer to Para. 4.B.
- disconnect the connector between the cable 2HF2 and the sensing element 1HF2
- connect the 9240SI CONTROLLER-LOOP between the connector 1HA2-AA/6B and the ground
- do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- replace the CABLE-CONNECTING, ENG 2 PYLON [2HF2] AMM 36-22-15-000-001 and AMM 36-22-15-400-001
- do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- do a check and repair the wiring between the pin AA/6B of the BMC2 (1HA2) and the cable 2HF2
- connect all the cables or connectors disconnected
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- install the BMC2 (1HA2) AMM 36-11-34-400-001
- refer to Para. 4.B.
- connect all the cables or connectors disconnected
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- install the BMC2 (1HA2) AMM 36-11-34-400-001
- refer to Para. 4.B.
- disconnect the connector between the cable 3HF2 and the sensing element 1HF2
- connect the connector between the cable 2HF2 and the sensing element 1HF2
- do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
- replace the SNSG ELEM-OVHT, ENG 2 PYLON [1HF2]
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- install the BMC-2 [1HA2] which is removed AMM 36-11-34-400-001
- refer to Para. 4.B.
- replace the CABLE ASSY [3HF2]
- connect all the cables or connectors disconnected
- do a check of the impedance read on the 9240SI CONTROLLER-LOOP
. if the impedance is less than 17 KOhms:
- do a check and repair the wiring between the pin AA/5B of the BMC2 (1HA2) and the cable 3HF2
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- install the BMC2 (1HA2) AMM 36-11-34-400-001
- refer to Para. 4.B.
. if the impedance is more than 17 KOhms:
- disconnect the 9240SI CONTROLLER-LOOP from the BMC2 connector
- install the BMC2 (1HA2) AMM 36-11-34-400-001
- refer to Para. 4.B.
B. Do the test given in Para. 3.