W DOC AIRBUS | TSM A320F

Leak Detection on the Engine 1 Pylon


TASK 36-22-00-810-830-A
Leak Detection on the Engine 1 Pylon


1. Possible Causes
  • BMC-1 [1HA1]
  • CABLE-CONNECTING, ENG 1 PYLON [2HF1]
  • wiring
  • SNSG ELEM-OVHT, ENG 1 PYLON [1HF1]
  • CABLE ASSY [3HF1]
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
9240SI
1
CONTROLLER-LOOP
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
ASM 362201
AMM 36-22-15-000-001
Removal of the Pylon Overheat Sensing-Element
AMM 36-22-15-400-001
Installation of the Pylon Overheat Sensing-Element
3. Fault Confirmation
Subtask 36-22-00-710-085-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC1 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-22-00-810-080-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
ENG1 PYLON LOOP
  • remove the BMC1 (1HA1) AMM 36-11-34-000-001
  • on the shelf 95VU, connect the 9240SI CONTROLLER-LOOP between the connector 1HA1-AA/5B and the ground ASM 362201
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
   (1) If the impedance is more than 17 KOhms:
   (2) If the impedance is less than 17 KOhms:
  • disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
  • do a visual inspection of the sensing elements and cables on the engine 1 pylon loop.
     (a) If a sensing element or cable is damaged:
     (b) If no sensing element is damaged:
  • disconnect the connector between the cable 2HF1 and the sensing element 1HF1
  • connect the 9240SI CONTROLLER-LOOP between the connector 1HA1-AA/5B and the ground
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
       1 If the impedance is less than 17 KOhms:
         a If the impedance is less than 17 KOhms:
  • do a check and repair the wiring between the pin AA/5B of the BMC1 (1HA1) and the cable 2HF1
  • connect all the cables or connectors disconnected
  • disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
  • install the BMC1 (1HA1) AMM 36-11-34-400-001
  • refer to Para. 4.B.
         b If the impedance is more than 17 KOhms:
  • connect all the cables or connectors disconnected
  • disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
  • install the BMC1 (1HA1) AMM 36-11-34-400-001
  • refer to Para. 4.B.
       2 If the impedance is more than 17 KOhms:
  • disconnect the connector between the cable 3HF1 and the sensing element 1HF1
  • connect the connector between the cable 2HF1 and the sensing element 1HF1
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 302 KOhms:
  • replace the SNSG ELEM-OVHT, ENG 1 PYLON [1HF1]
  • disconnect the 9240SI CONTROLLER-LOOP from the BMC connector
  • install the BMC-1 [1HA1] which is removed AMM 36-11-34-400-001
  • refer to Para. 4.B.
         b If the impedance is more than 302 KOhms:
  • replace the CABLE ASSY [3HF1]
  • connect all the cables or connectors disconnected
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP
    . if the impedance is less than 17 KOhms:
    - do a check and repair the wiring between the pin AA/6B of the BMC1 (1HA1) and the cable 3HF1
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.B.
    . if the impedance is more than 17 KOhms:
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.B.
Subtask 36-22-00-710-086-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:06 UTC