W DOC AIRBUS | TSM A320F

Leak Detection from the Loop A in the Left Wing


TASK 36-22-00-810-825-A
Leak Detection from the Loop A in the Left Wing


1. Possible Causes
  • CABLE-CONNECTING, L WING LOOP A [21HF]
  • SNSG ELEM-OVHT, L WING LOOP A [81HF]
  • SNSG ELEM-OVHT, L WING LOOP A [22HF]
  • SNSG ELEM-OVHT, L WING LOOP A [23HF]
  • CABLE-CONNECTING, L WING LOOP A [24HF]
  • CABLE-CONNECTING, L WING LOOP A [25HF]
  • SNSG ELEM-OVHT, L WING LOOP A [26HF]
  • SNSG ELEM-OVHT, L WING LOOP A [27HF]
  • SNSG ELEM-OVHT, L WING LOOP A [28HF]
  • SNSG ELEM-OVHT, L WING LOOP A [29HF]
  • OVHT SENS ELEMENT [73HF]
  • OVHT SENS ELEMENT [31HF]
  • OVERHEAT SENSING ELEM [32HF]
  • OVHT SENS ELEMENT [33HF]
  • OVHT SENS ELEMENT [34HF]
  • OVHT SENS ELEMENT [35HF]
  • OVHT SENS ELEMENT [36HF]
  • CABLE ASSY [30HF]
  • wiring
  • INTERCONNECTING CABLE [90HF]
  • duct
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
9240SI
1
CONTROLLER-LOOP
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-720-004
Leak Check of Engine Bleed Air Supply System and Packs Components through HPGC
AMM 36-11-00-720-005
Leak Check of Engine Bleed Air Supply System and Packs Components with APU Bleed Air
AMM 36-11-00-720-809
Leak Check of the LH Wing using Bleed Air from the opposite Engine 2
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
AMM 36-22-00-790-001
Leak Check on all the Bleed Air Ducts and Packs Components
ASM 362201
AMM 36-22-16-000-001
Removal of the Overheat Sensing Elements
AMM 36-22-16-000-002
Removal of the Cables
AMM 36-22-16-000-003
Removal of the Cables
AMM 36-22-16-000-004
Removal of the Overheat Sensing Elements
AMM 36-22-16-000-005
Removal of the Overheat Sensing Elements
AMM 36-22-16-000-006
Removal of the Overheat Sensing Elements
AMM 36-22-16-000-007
Removal of the Cables
AMM 36-22-16-400-001
Installation of the Overheat Sensing Elements
AMM 36-22-16-400-002
Installation of the Cables
AMM 36-22-16-400-003
Installation of the Cables
AMM 36-22-16-400-004
Installation of the Overheat Sensing Elements
AMM 36-22-16-400-005
Installation of the Overheat Sensing Elements
AMM 36-22-16-400-007
Installation of the Overheat Sensing Elements
AMM 36-22-16-400-008
Installation of the Cables
AMM 36-22-18-000-001
Removal of the Fuselage Overheat Sensing-Elements (Loop A and B)
AMM 36-22-18-400-001
Installation of the Fuselage Overheat Sensing-Elements (Loop A and B)
3. Fault Confirmation
Subtask 36-22-00-710-075-A ** ON A/C NOT FOR ALL
A. Test
NOTE: The overheat detection threshold is between 117 and 131 degrees Celsius.
An overheat detection by one loop can occur in these conditions :
  • high Outside Air Temperature (OAT),
  • ECS supplied with hot bleed air.
    In these conditions, the ambient air around the sensing elements can increase to the detection threshold but there is not an air leak.
    If there is an air leak, there will be an AIR L(R) WING LEAK warning on the ECAM.
    No other maintenance action is necessary if:
  • the overheat detection was by one loop only with high OAT and ECS supplied with hot bleed air,
  • the result of the BMC BITE test is TEST OK.
   (1) Do the BITE test of the BMC1 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-22-00-810-075-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
L WING LOOP A
  • remove BMC1 (1HA1) AMM 36-11-34-000-001
  • on the shelf 95VU, connect the 9240SI CONTROLLER-LOOP between the connector 1HA1-AA/3B and the ground ASM 362201
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
   (1) If the impedance is more than 10 KOhms:
  • Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
  • Install BMC1 (1HA1) AMM 36-11-34-400-001.
  • Refer to Para. 4.C.
  • Check the correct installation of sensing element along bleed duct.
  • Perform a wiring check.
   (2) If the impedance is less than 10 KOhms:
  • disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
  • do a visual inspection of the sensing elements and cables on the L wing loop A.
     (a) If a sensing element or cable is damaged:
     (b) If no sensing element is damaged:

The elements that follow can be found in the WING:

  • Disconnect the connector between the sensing elements 28HF and 29HF.
  • Connect the 9240SI CONTROLLER-LOOP between the connector 1HA1-AA/3B and the ground.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
NOTE: You must use a dichotomic method to find the defective sensing element:
  • Disconnect a connector in the middle of a sensing line.
  • Measure the resistance of one of the halves.
    If the measurement is correct, you must do a check of the other half.
    If the measurement is not correct, do the same operation in the defective half again until you find the defective sensing element.
       1 If the impedance is less than 10 KOhms:
  • disconnect the connector between the cables 24HF and 25HF
  • do a check of the impedance read or the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 10 KOhms:
  • disconnect the connector between the sensing elements 81HF and 22HF
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 131 KOhms:
    - disconnect the connector between the cable 21HF and the sensing element 81HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP

    ** If the impedance is less than 10 KOhms:
    - replace the CABLE-CONNECTING, L WING LOOP A [21HF] AMM 36-22-16-000-002 and AMM 36-22-16-400-002
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - do a check and repair the wiring between the pin AA/3B of the BMC1 (1HA1) and the cable 21HF
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [81HF] AMM 36-22-16-000-001 and AMM 36-22-16-400-001
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    * If the impedance is more than 131 KOhms:
    - disconnect the connector between the sensing elements 22HF and 23HF
    - connect the connector between the sensing elements 81HF and 22HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [22HF] AMM 36-22-16-000-006 and AMM 36-22-16-400-007
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - disconnect the connector between the sensing element 23HF and the cable 24HF
    - connect the connector between the sensing elements 22HF and 23HF
    - do a check of the impedance read in the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [23HF] AMM 36-22-16-000-005 and AMM 36-22-16-400-005
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - replace the CABLE-CONNECTING, L WING LOOP A [24HF] AMM 36-22-16-000-003 and AMM 36-22-16-400-003
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.
         b If the impedance is more than 10 KOhms:
  • disconnect the connector between the sensing elements 26HF and 27HF
  • connect the connector between the cables 24HF and 25HF
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 KOhms:
    - disconnect the connector between the cable 25HF and the sensing element 26HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - replace the CABLE-CONNECTING, L WING LOOP A [25HF] AMM 36-22-16-000-007 and AMM 36-22-16-400-008
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [26HF] AMM 36-22-16-000-004 and AMM 36-22-16-400-004
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    * If the impedance is more than 10 KOhms:
    - disconnect the connector between the sensing elements 27HF and 28HF
    - connect the connector between the sensing elements 26HF and 27HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [27HF] AMM 36-22-16-000-005 and AMM 36-22-16-400-005
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [28HF] AMM 36-22-16-000-006 and AMM 36-22-16-400-007
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.
       2 If the impedance is more than 10 KOhms:
  • disconnect the connector between the sensing elements 32HF (found in the fuselage) and 33HF (found in the fuselage).
  • connect the connector between the sensing elements 28HF (found in the wing) and 29HF (found in the wing).
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 10 KOhms:
  • disconnect the connector between the sensing elements 73HF and 31HF
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 KOhms:
    - disconnect the connector between the sensing elements 29HF (found in the wing) and 73HF (found in the fuselage).
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - replace the SNSG ELEM-OVHT, L WING LOOP A [29HF] (found in the wing) AMM 36-22-16-000-001 and AMM 36-22-16-400-001
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

The elements that follow can be found in the FUSALAGE:

** If the impedance is more than 10 KOhms:
- replace the OVHT SENS ELEMENT [73HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
- connect all the cables or connectors disconnected
- disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
- install the BMC1 (1HA1) AMM 36-11-34-400-001
- refer to Para. 4.C.

* If the impedance is more than 10 KOhms:
- disconnect the connector between the sensing elements 31HF and 32HF
- connect the connector between the sensing elements 73HF and 31HF
- do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

** If the impedance is less than 10 KOhms:
- replace the OVHT SENS ELEMENT [31HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
- connect all the cables or connectors disconnected
- disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
- install the BMC1 (1HA1) AMM 36-11-34-400-001
- refer to Para. 4.C.

** If the impedance is more than 10 KOhms:
- replace the OVERHEAT SENSING ELEM [32HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
- connect all the cables or connectors disconnected
- disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
- install the BMC1 (1HA1) AMM 36-11-34-400-001
- refer to Para. 4.C.
         b If the impedance is more than 10 KOhms:
  • disconnect the connector between the sensing elements 35HF and 36HF
  • connect the connector between the sensing elements 32HF and 33HF
  • do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 KOhms:
    - disconnect the connector between the sensing elements 33HF and 34HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - replace the OVHT SENS ELEMENT [33HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - disconnect the connector between the sensing elements 34HF and 35HF
    - connect the connector between the sensing elements 33HF and 34HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - replace the OVHT SENS ELEMENT [34HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - replace the OVHT SENS ELEMENT [35HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    * If the impedance is more than 10 KOhms:
    - disconnect the connector between the sensing element 36HF and the cable 30HF
    - connect the connector between the sensing elements 35HF and 36HF
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - replace the OVHT SENS ELEMENT [36HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
    - connect all the cables or connectors disconnected
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - replace the CABLE ASSY [30HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001
    - connect all the cables or connectors disconnected
    - do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - do a check and repair the wiring between the pin AA/4B of the BMC1 (1HA1) and the cable 30HF
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector
    - install the BMC1 (1HA1) AMM 36-11-34-400-001
    - refer to Para. 4.C.
Subtask 36-22-00-810-075-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
L WING LOOP A
  • Remove BMC1 (1HA1) AMM 36-11-34-000-001.
  • On shelf 95VU, connect the 9240SI CONTROLLER-LOOP between connector 1HA1-AA/3B and the ground ASM 362201.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
   (1) If the impedance is more than 10 KOhms:
  • Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
  • Install BMC1 (1HA1) AMM 36-11-34-400-001.
  • Refer to Para. 4.C.
  • Check the correct installation of sensing element along bleed duct.
  • Perform a wiring check.
   (2) If the impedance is less than 10 KOhms:
  • Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
  • Do a visual inspection of the sensing elements and cables on the L wing loop A.
     (a) If a sensing element or cable is damaged:
     (b) If no sensing element is damaged:

The elements that follow can be found in the WING:

  • Disconnect the connector between the sensing elements 28HF and 29HF.
  • Connect the 9240SI CONTROLLER-LOOP between connector 1HA1-AA/3B and the ground.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
NOTE: You must use a dichotomic method to find the defective sensing element:
  • Disconnect a connector in the middle of a sensing line.
  • Measure the resistance of one of the halves.
    If the measurement is correct, you must do a check of the other half.
    If the measurement is not correct, do the same operation in the defective half again until you find the defective sensing element.
       1 If the impedance is less than 10 KOhms:
  • Disconnect the connector between the cables 24HF and 25HF.
  • Do a check of the impedance read or the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 10 KOhms:
  • Disconnect the connector between the sensing elements 81HF and 22HF.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 131 KOhms:
    - Disconnect the connector between the cable 21HF and the sensing element 81HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the CABLE-CONNECTING, L WING LOOP A [21HF] AMM 36-22-16-000-002 and AMM 36-22-16-400-002.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - Do a check and repair the wiring between pin AA/3B of the BMC1 (1HA1) and the cable 21HF.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [81HF] AMM 36-22-16-000-001 and AMM 36-22-16-400-001.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    * If the impedance is more than 131 KOhms:
    - Disconnect the connector between the sensing elements 22HF and 23HF.
    - Connect the connector between the sensing elements 81HF and 22HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [22HF] AMM 36-22-16-000-006 and AMM 36-22-16-400-007.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - Disconnect the connector between the sensing element 23HF and the cable 24HF.
    - Connect the connector between the sensing elements 22HF and 23HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [23HF] AMM 36-22-16-000-005 and AMM 36-22-16-400-005.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - Replace the CABLE-CONNECTING, L WING LOOP A [24HF] AMM 36-22-16-000-003 and AMM 36-22-16-400-003.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.
         b If the impedance is more than 10 KOhms:
  • Disconnect the connector between the sensing elements 26HF and 27HF.
  • Connect the connector between the cables 24HF and 25HF.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 KOhms:
    - Disconnect the connector between the cable 25HF and the sensing element 26HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the CABLE-CONNECTING, L WING LOOP A [25HF] AMM 36-22-16-000-007 and AMM 36-22-16-400-008.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [26HF] AMM 36-22-16-000-004 and AMM 36-22-16-400-004.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    * If the impedance is more than 10 KOhms:
    - Disconnect the connector between the sensing elements 27HF and 28HF.
    - Connect the connector between the sensing elements 26HF and 27HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [27HF] AMM 36-22-16-000-005 and AMM 36-22-16-400-005.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [28HF] AMM 36-22-16-000-006 and AMM 36-22-16-400-007.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.
       2 If the impedance is more than 10 KOhms:
  • Disconnect the connector between the sensing elements 32HF (found in the fuselage) and 33HF (found in the fuselage).
  • Connect the connector between the sensing elements 28HF (found in the wing) and 29HF (found in the wing).
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.
         a If the impedance is less than 10 KOhms:
  • Disconnect the connector between the sensing elements 73HF and 31HF.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 KOhms:
    - Disconnect the connector between the sensing element 29HF (found in the wing) and the cable 90HF (found in the fuselage).
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the SNSG ELEM-OVHT, L WING LOOP A [29HF] (found in the wing) AMM 36-22-16-000-001 and AMM 36-22-16-400-001.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

The elements that follow can be found in the FUSELAGE:

** If the impedance is more than 10 KOhms:
- Disconnect the connector between the cable 90HF and the sensing element 73HF.
- Connect the connector between the sensing element 29HF and the cable 90HF.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

*** If the impedance is less than 10 KOhms:
- Replace the INTERCONNECTING CABLE [90HF] .
- Connect all the disconnected cables or connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.C.

*** If the impedance is more than 10 KOhms:
- Replace the OVHT SENS ELEMENT [73HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
- Connect all the disconnected cables or connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.C.

* If the impedance is more than 10 KOhms:
- Disconnect the connector between the sensing elements 31HF and 32HF.
- Connect the connector between the sensing elements 73HF and 31HF.
- Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

** If the impedance is less than 10 KOhms:
- Replace the OVHT SENS ELEMENT [31HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
- Connect all the disconnected cables or connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.C.

** If the impedance is more than 10 KOhms:
- Replace the OVERHEAT SENSING ELEM [32HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
- Connect all the disconnected cables or connectors.
- Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
- Install the BMC1 (1HA1) AMM 36-11-34-400-001.
- Refer to Para. 4.C.
         b If the impedance is more than 10 KOhms:
  • Disconnect the connector between the sensing elements 35HF and 36HF.
  • Connect the connector between the sensing elements 32HF and 33HF.
  • Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    * If the impedance is less than 10 KOhms:
    - Disconnect the connector between the sensing elements 33HF and 34HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the OVHT SENS ELEMENT [33HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - Disconnect the connector between the sensing elements 34HF and 35HF.
    - Connect the connector between the sensing elements 33HF and 34HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - Replace the OVHT SENS ELEMENT [34HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - Replace the OVHT SENS ELEMENT [35HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    * If the impedance is more than 10 KOhms:
    - Disconnect the connector between the sensing element 36HF and the cable 30HF.
    - Connect the connector between the sensing elements 35HF and 36HF.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    ** If the impedance is less than 10 KOhms:
    - Replace the OVHT SENS ELEMENT [36HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
    - Connect all the disconnected cables or connectors.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    ** If the impedance is more than 10 KOhms:
    - Replace the CABLE ASSY [30HF] AMM 36-22-18-000-001 and AMM 36-22-18-400-001.
    - Connect all the disconnected cables or connectors.
    - Do a check of the impedance read on the 9240SI CONTROLLER-LOOP.

    *** If the impedance is less than 10 KOhms:
    - Do a check and repair the wiring between pin AA/4B of the BMC1 (1HA1) and the cable 30HF.
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001.
    - Refer to Para. 4.C.

    *** If the impedance is more than 10 KOhms:
    - Disconnect the 9240SI CONTROLLER-LOOP from the BMC1 connector.
    - Install the BMC1 (1HA1) AMM 36-11-34-400-001
    - Refer to Para. 4.C.
Subtask 36-22-00-810-083-A ** ON A/C NOT FOR ALL
B. If the test gives the TEST OK message:
Subtask 36-22-00-710-076-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:04 UTC