Loss of the Left-Wing Leak Detection
TASK 36-22-00-810-815-A
Loss of the Left-Wing Leak Detection
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-066-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-064-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:03 UTC
Loss of the Left-Wing Leak Detection
1. Possible Causes
- BMC-1 [1HA1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-22-00-810-809-A | Loss of the Leak Detection Loop B on the Left Wing |
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
Subtask 36-22-00-710-066-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-064-B ** ON A/C NOT FOR ALL
A. If the test gives these two maintenance messages:
- on the BMC1:
BMC1 - and on the BMC2:
L WING LOOP B INOP: - replace the BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.