Loss of the Left-Wing Leak Detection
TASK 36-22-00-810-813-A
Loss of the Left-Wing Leak Detection
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-062-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:03 UTC
Loss of the Left-Wing Leak Detection
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-22-00-810-807-A | Loss of the Leak Detection Loop A on the Left Wing |
| TSM TASK 36-22-00-810-809-A | Loss of the Leak Detection Loop B on the Left Wing |
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
Subtask 36-22-00-710-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-062-B ** ON A/C NOT FOR ALL
A. If the test gives these two maintenance messages:
- on the BMC1
L WING LOOP A INOP - on the BMC2
L WING LOOP B INOP - do this trouble shooting procedure (Ref. TSM TASK 36-22-00-810-807) and (Ref. TSM TASK 36-22-00-810-809).