Loss of the Leak Detection Loop of the APU
TASK 36-22-00-810-812-A
Loss of the Leak Detection Loop of the APU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-22-00-710-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-061-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:03 UTC
Loss of the Leak Detection Loop of the APU
1. Possible Causes
- BMC-1 [1HA1]
- wiring
- sensing element
wiring from the connector AA/7B to the sensing element (12HF) wiring from the sensing element (19HF) to the connector AA/8B
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-22-00-100-801 | Clean the Overheat Detection System (OHDS) Connectors and Apply the Electrical Insulating Compound |
| ASM 362201 | |
| AMM 36-22-17-000-001 | Removal of the APU Overheat Sensing-Elements |
| AMM 36-22-17-400-001 | Installation of the APU Overheat Sensing-Elements |
Subtask 36-22-00-710-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-22-00-810-061-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
APU LOOP INOP OR BMC IDENT CKT:
Subtask 36-22-00-710-063-A ** ON A/C NOT FOR ALL APU LOOP INOP OR BMC IDENT CKT:
- remove the BMC-1 [1HA1] AMM 36-11-34-000-001.
- do a continuity check of the APU loop from pin AA/7B of the BMC1 to pin AA/8B of the BMC1 ASM 362201.
NOTE: This procedure is related to the loss of the APU-loop detection signal or to incorrect continuity of the loop.
The resistance of the loop must be less than 15 ohms at ambient temperature.
The BMC gives the maintenance message when the resistance of the loop is more than 75 ohms (discontinuity).
There is continuity when the resistance of the loop is less than 75 ohms.
(1) If there is continuity and the resistance of the loop is between 15 ohms and 75 ohms: The resistance of the loop must be less than 15 ohms at ambient temperature.
The BMC gives the maintenance message when the resistance of the loop is more than 75 ohms (discontinuity).
There is continuity when the resistance of the loop is less than 75 ohms.
- do a check for a ground signal at pin AA/9A of the BMC1.
- repair the wiring .
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a check and clean all the connections ASM 362201 to remove contamination and decrease the resistance of the loop AMM 36-22-00-100-801.
- replace the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a check of the wiring from pin AA/7B of the BMC1 to the cable (11HF) and from pin AA/8B of the BMC1 to the cable (20HF) ASM 362201.
- repair the wiring .
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a visual inspection of the sensing elements on the APU loop.
- replace the sensing element .
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a continuity check of each sensing element, one after the other.
- replace the sensing element AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- install the BMC-1 [1HA1] AMM 36-11-34-400-001.
- do a check and repair the
wiring from the connector AA/7B to the sensing element (12HF) ASM 362201. - do a check and repair the
wiring from the sensing element (19HF) to the connector AA/8B ASM 362201. - install the BMC-1 [1HA1] AMM 36-11-34-400-001.
B. Do the test given in Para. 3.