Slow Operation of the Crossbleed Valve
TASK 36-12-00-810-811-A
Slow Operation of the Crossbleed Valve
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-12-00-710-064-A ** ON A/C NOT FOR ALL
Subtask 36-12-00-810-067-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:00 UTC
Slow Operation of the Crossbleed Valve
1. Possible Causes
- CROSSBLEED VALVE ACTUATOR
- CROSSBLEED VALVE [6HV]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-12-00-710-802 | Operational Test of the APU Bleed Air Supply and Crossbleed Systems |
| AMM 36-12-52-000-001 | Removal of the Crossbleed Valve |
| AMM 36-12-52-000-002 | Removal of the Crossbleed Valve Actuator |
| AMM 36-12-52-400-001 | Installation of the Crossbleed Valve |
| AMM 36-12-52-400-002 | Installation of the Crossbleed Valve Actuator |
Subtask 36-12-00-710-064-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU bleed-air supply and the crossbleed systems AMM 36-12-00-710-802.
4. Fault IsolationSubtask 36-12-00-810-067-A ** ON A/C NOT FOR ALL
A. If after the test message X-BLEED MAN CTL is shown on the status page of the lower ECAM display unit:
Subtask 36-12-00-810-068-A ** ON A/C NOT FOR ALL - Look at the visual position indicator of the crossbleed valve to make sure that the indicator shows the fully closed position.
- Set the X-BLEED selector switch on AIR COND overhead panel 30VU to the OPEN position.
- Do a check of the operation time of the crossbleed valve from the fully closed to the fully open position.
- Replace the CROSSBLEED VALVE ACTUATOR AMM 36-12-52-000-002 and AMM 36-12-52-400-002.
B. If the fault continues:
(1) Replace the CROSSBLEED VALVE [6HV] AMM 36-12-52-000-001 and AMM 36-12-52-400-001.
Subtask 36-12-00-710-065-A ** ON A/C NOT FOR ALL (1) Replace the CROSSBLEED VALVE [6HV] AMM 36-12-52-000-001 and AMM 36-12-52-400-001.
C. Do the test given in Para. 3.