APU Loop Inoperative
TASK 36-12-00-810-808-A
APU Loop Inoperative
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 36-12-00-710-060-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-12-00-810-065-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:00 UTC
APU Loop Inoperative
1. Possible Causes
- wiring
- BMC-1 [1HA1]
- SENSING ELEMENT-OVERHEAT,WING [11HF]
- OVHT SENS ELEMENT [12HF]
- OVHT SENS ELEMENT [13HF]
- OVHT SENS ELEMENT [14HF]
- OVHT SENS ELEMENT [15HF]
- OVHT SENS ELEMENT [16HF]
- OVHT SENS ELEMENT [17HF]
- OVHT SENS ELEMENT [18HF]
- OVHT SENS ELEMENT [19HF]
- CABLE ASSY [20HF]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 9240SI | 1 | CONTROLLER-LOOP |
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-22-00-810-879-A | APU Leak Detection |
| ESPM 204422 | |
| AMM 36-11-00-740-802 | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
| AMM 36-22-00-100-803 | Clean the Overheat Detection System (OHDS) Connectors and Apply the Electrical Insulating Compound |
| ASM 362201 | |
| AWM 362201 | |
| AMM 36-22-17-000-001 | Removal of the APU Overheat Sensing-Elements |
| AMM 36-22-17-400-001 | Installation of the APU Overheat Sensing-Elements |
Subtask 36-12-00-710-060-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-12-00-810-065-B ** ON A/C NOT FOR ALL
A. If the test gives one of these maintenance messages:
Subtask 36-12-00-810-074-A ** ON A/C NOT FOR ALL - APU LOOP OPEN
- APU LOOP INOP OPEN
or - APU LOOP INOP SHORT.
NOTE: This procedure is applicable when there is a loss of the APU loop detection-signal or to the incorrect continuity of the loop.
- Remove BMC-1 AMM 36-11-34-000-001.
- On shelf 95VU, connect the 9240SI CONTROLLER-LOOP between BMC-1 pin AA/4C and AA/5C ASM 362201.
- Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
- On shelf 95VU, connect the 9240SI CONTROLLER-LOOP between connector BMC-1 pin AA/6E and the ground ASM 362201.
- Do a check of the insulation resistance shown on the 9240SI CONTROLLER-LOOP.
- Go to Para. 4.B.
- Do the fault isolation steps (Ref. TSM TASK 36-22-00-810-879).
- Connect the 9240SI CONTROLLER-LOOP between connector 1969VC pin A/19 to A/20 AWM 362201.
- Do a visual inspection of the sensing elements and the connecting cables on the APU loop.
- Disconnect the 9240SI CONTROLLER-LOOP from connector 1969VC pin A/19 to A/20.
- Replace the defective sensing element or connecting cable AMM 36-22-17-000-001 and AMM 36-22-17-400-001.
- Install BMC-1 AMM 36-11-34-400-001.
- Go to Para. 4.B.
- Connect the 9240SI CONTROLLER-LOOP between connector 1969VC pin A/19 and BMC-1 pin AA/4C AWM 362201.
- Disconnect the 9240SI CONTROLLER-LOOP from connector 1969VC pin A/19 and BMC-1 pin AA/4C.
- Repair or replace the wiring ESPM 204422.
- Install BMC-1 AMM 36-11-34-400-001.
- Connect the 9240SI CONTROLLER-LOOP between connector 1969VC pin A/20 and BMC-1 pin AA/5C AWM 362201.
- Repair or replace the wiring ESPM 204422.
- Install BMC-1 AMM 36-11-34-400-001.
- Do the cleaning procedure AMM 36-22-00-100-803.
- Do the BITE test of the EBAS AMM 36-11-00-740-802.
* If the fault continues:
** Replace BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
B. Dichotomy Procedure
(1) Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
(a) If the continuity resistance value is more than 16 Ohms:
NOTE: The purpose of this procedure is to find and isolate the elements that causes a high continuity resistance on the leak detection loop of the APU.
(1) Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
(a) If the continuity resistance value is more than 16 Ohms:
- Disconnect the connecting cable (11HF) of connector 1969VC pin A/19 and the connecting cable (20HF) of the connector 1969VC pin A/20. Disconnect one after the other all the sensing elements between the connection cables (11HF) and (20HF) AMM 36-22-17-000-001.
- Measure the continuity resistance with the 9240SI CONTROLLER-LOOP between the center pin on the two ends of each of the elements.
- Do a check of the continuity resistance shown on the 9240SI CONTROLLER-LOOP:
- Disconnect the 9240SI CONTROLLER-LOOP.
- Replace the defective elements:
SENSING ELEMENT-OVERHEAT,WING [11HF] or
OVHT SENS ELEMENT [12HF] or
OVHT SENS ELEMENT [13HF] or
OVHT SENS ELEMENT [14HF] or
OVHT SENS ELEMENT [15HF] or
OVHT SENS ELEMENT [16HF] or
OVHT SENS ELEMENT [17HF] or
OVHT SENS ELEMENT [18HF] or
OVHT SENS ELEMENT [19HF] or
CABLE ASSY [20HF]
AMM 36-22-17-000-001 and AMM 36-22-17-400-001. - Install BMC-1 AMM 36-11-34-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP.
- Clean all the connections of the sensing elements and the connecting cables to remove contamination and decrease the resistance of the loop AMM 36-22-00-100-803 AWM 362201.
- Connect again all the sensing elements or connecting cables disconnected AMM 36-22-17-400-001.
- Install BMC-1 AMM 36-11-34-400-001.
- Disconnect the 9240SI CONTROLLER-LOOP.
- Connect again all the sensing elements or connecting cables disconnected AMM 36-22-17-400-001.
- Replace BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.