W DOC AIRBUS | TSM A320F

To Slow Operation of the Crossbleed Valve


TASK 36-12-00-810-806-A
To Slow Operation of the Crossbleed Valve


1. Possible Causes
  • VALVE-X BLEED ACTUATOR
  • CROSSBLEED VALVE [6HV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-12-00-710-001
Operational Test of the APU Bleed Air Supply and Crossbleed Systems
AMM 36-12-52-000-001
Removal of the Crossbleed Valve
AMM 36-12-52-000-002
Removal of the Crossbleed Valve Actuator
AMM 36-12-52-400-001
Installation of the Crossbleed Valve
AMM 36-12-52-400-002
Installation of the Crossbleed Valve Actuator
3. Fault Confirmation
Subtask 36-12-00-710-058-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU bleed-air supply and the crossbleed systems AMM 36-12-00-710-001.
4. Fault Isolation
Subtask 36-12-00-810-059-A ** ON A/C NOT FOR ALL
A. If after the test the message X-BLEED MAN CTL is shown on the status page of the lower ECAM display unit:
  • look at the visual position indicator of the crossbleed valve to make sure that the indicator shows fully closed position,
  • set the X-BLEED selector switch on AIR COND overhead panel 30VU to the OPEN position,
  • do a check of the operation time of the crossbleed valve from fully closed to fully open position .
   (1) If the operation time of the crossbleed valve is more than 10 s:
   (2) If the fault continues:
Subtask 36-12-00-710-059-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:00 UTC