W DOC AIRBUS | TSM A320F

Low Air Pressure in the Right Crossbleed Duct


TASK 36-12-00-810-804-A
Low Air Pressure in the Right Crossbleed Duct


1. Possible Causes
  • CROSSBLEED VALVE [6HV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 12-33-21-618-001
Pre-conditioning through the LP Ground Connection
AMM 36-12-52-000-001
Removal of the Crossbleed Valve
AMM 36-12-52-400-001
Installation of the Crossbleed Valve
3. Fault Confirmation
Subtask 36-12-00-710-056-A ** ON A/C NOT FOR ALL
A. Do the pre-conditioning with the high-pressure ground connection AMM 12-33-21-618-001 or with the APU AMM 12-33-21-618-001.
NOTE: Make sure that there are no maintenance messages related to the pack 2 and/or the crossbleed system available before you do this test.
4. Fault Isolation
Subtask 36-12-00-810-057-A ** ON A/C NOT FOR ALL
A. If the right pack does not operate during the pre-conditioning because of low pressure:
Subtask 36-12-00-710-057-A ** ON A/C NOT FOR ALL
B. Do the test as given in Para. 3. to make sure that the operation is correct (no maintenance message shown).
[Rev.8 from Aug 2018] 2026.04.04 04:34:00 UTC