Disagreement of the Position Switches of the Crossbleed Valve


TASK 36-12-00-810-803-A
Disagreement of the Position Switches of the Crossbleed Valve


1. Possible Causes
  • CROSSBLEED VALVE [6HV]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
ASM 361201
AMM 36-12-52-000-002
Removal of the Crossbleed Valve Actuator
AMM 36-12-52-400-002
Installation of the Crossbleed Valve Actuator
AMM 49-00-00-860-005
APU Start by External Power
AMM 49-00-00-860-006
APU Shutdown by External Power
AMM 49-00-00-860-008
APU Start by External Power
AMM 49-00-00-860-009
APU Shutdown by External Power (131-9(A))
3. Fault Confirmation
Subtask 36-12-00-710-054-B ** ON A/C NOT FOR ALL
A. Test
   (1) Start the APU AMM 49-00-00-860-005.
   (2) Do the operational test of both BMCs AMM 36-11-00-740-001.
   (3) Stop the APU AMM 49-00-00-860-006.
Subtask 36-12-00-710-054-C ** ON A/C NOT FOR ALL
A. Test
   (1) Start the APU AMM 49-00-00-860-008.
   (2) Do the operational test of both BMCs AMM 36-11-00-740-001.
   (3) Stop the APU AMM 49-00-00-860-009.
4. Fault Isolation
Subtask 36-12-00-810-055-A ** ON A/C NOT FOR ALL
A. If both BMCs give the maintenance message X FEED-V 6HV OR CKT:
   (1) If the fault continues:
  • do a check and repair the wiring between:
    the BMC-1, BMC-2 (1HA1/2) AB/1A,2A and the CROSSBLEED VALVE [6HV] A/F,D ASM 361201,
  • do a check and repair the wiring between:
    the CROSSBLEED VALVE [6HV] A/N and ground ASM 361201.
   (2) If the fault continues:
  • do a check and repair the wiring between:
    the BMC-1, BMC-2 (1HA1/2) connectors AB/3A,4A and the CROSSBLEED-VALVE SELECTOR SWITCH (3HV) connectors A/2,4 ASM 361201,
  • do a check and repair the wiring between:
    the CROSSBLEED-VALVE SELECTOR SWITCH (3HV) connector A/1 and ground ASM 361201.
Subtask 36-12-00-810-056-A ** ON A/C NOT FOR ALL
B. If only one BMC gives the maintenance message X FEED VALVE 6HV OR CKT:
   (1) If the fault continues:
  • do a check and repair the wiring between:
    the related BMC connectors AB/1A,2A,3A,4A and the first terminal block ASM 361201.
Subtask 36-12-00-710-055-A ** ON A/C NOT FOR ALL
C. Do the test as given in Para. 3. to make sure that the operation is correct (no maintenance message shown).