W DOC AIRBUS | TSM A320F

Failure of Regulation of the Bleed-Pressure Regulating Valve during Take-Off on Engine 2


TASK 36-11-00-810-B39-A
Failure of Regulation of the Bleed-Pressure Regulating Valve during Take-Off on Engine 2


1. Possible Causes
  • VALVE-OVERPRESSURE, ENG 2 [5HA2]
  • sense line
  • VALVE-BLEED PRESS REG [4001HA]
  • VALVE-HP BLEED [4000HA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-710-003
Operational Test of the Bleed Air System
AMM 36-11-00-720-010
Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid with the Bleed Test Set P/N 99127B03
AMM 36-11-00-720-013
Functional Test of the Sense Line Connected between the Bleed-Pressure Regulator Valve and the Duct Assy with the Bleed Test Set P/N 99127B03
AMM 36-11-00-720-810
Pressure Regulating Test after Overpressure at Take Off Events with Bleed Test Set P/N 98L36103002000
AMM 36-11-49-000-027
Removal of the Sense Line between the Pylon Interface and the Duct Assy
AMM 36-11-49-000-028
Removal of the Sense Line between the Pylon Interface and the Duct Assy
AMM 36-11-49-000-029
Removal of the Pneumatic Sense Lines in the Pylon
AMM 36-11-49-000-820
Removal of the Pneumatic Sense Lines in the Pylon
AMM 36-11-49-400-027
Installation of the Sense Line between the Pylon Interface and the Duct Assy
AMM 36-11-49-400-028
Installation of the Sense Line between the Pylon Interface and the Duct Assy
AMM 36-11-49-400-029
Installation of the Pneumatic Sense Lines in the Pylon
AMM 36-11-49-400-820
Installation of the Pneumatic Sense Lines in the Pylon
AMM 36-11-51-000-040
Removal of the High Pressure Bleed Valve
AMM 36-11-51-000-042
Removal of the High Pressure Bleed Valve
AMM 36-11-51-400-040
Installation of the High Pressure Bleed Valve
AMM 36-11-51-400-042
Installation of the High Pressure Bleed Valve
AMM 36-11-52-000-040
Removal of the Bleed Pressure-Regulator Valve
AMM 36-11-52-000-042
Removal of the Bleed Pressure Regulator Valve
AMM 36-11-52-400-040
Installation of the Bleed Pressure-Regulator Valve
AMM 36-11-52-400-042
Installation of the Bleed Pressure Regulator Valve
AMM 36-11-53-000-001
Removal of the Overpressure Valve
AMM 36-11-53-400-001
Installation of the Overpressure Valve
AMM 36-11-53-720-001
Functional Test of the Overpressure Valves with the Bleed Test Set P/N 98D36003000000
3. Fault Confirmation
Subtask 36-11-00-710-643-A ** ON A/C NOT FOR ALL
A. Only do this trouble shooting procedure if is shown the warning message AIR ENG 2 BLEED FAULT and no maintenance message associated is shown.
4. Fault Isolation
Subtask 36-11-00-810-788-A ** ON A/C NOT FOR ALL
A. Functional Test
NOTE: It is necessary to make sure that the overpressure valve operates correctly after an overpressure at the take-off.
   (1) Do the functional test of the overpressure valve AMM 36-11-53-720-001.
     (a) If the test is not OK:
       1 Replace the VALVE-OVERPRESSURE, ENG 2 [5HA2] AMM 36-11-53-000-001 and AMM 36-11-53-400-001.
     (b) If the test is OK:
       1 Continue the troubleshooting procedure.
Subtask 36-11-00-810-789-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do the pressure regulator test of the pressure regulator valve AMM 36-11-00-720-810.
   (2) If the pressure value is lower than 42 psi (2.90 bar):
     (a) Do the functional test of the sense line between the pressure regulator valve and the pressure-regulator valve control-solenoid AMM 36-11-00-720-010.
       1 If the test is not OK:
       2 If the test is OK:
   (3) If the pressure value is more than 56 psi (3.86 bar):
     (a) For PRV 6774G with sense line 6 installed:
       1 Do a functional test of the sense line connected between the bleed pressure regulator valve and the duct assy AMM 36-11-00-720-013.
         a If the test is not OK:
         b If the test is OK:
     (b) For the PRV 6774G without sense line 6 installed:
       1 Do a check of the blancking plug of the IPT and RPT.
         a If the blanking plug is damaged, replace it.
         b If the blanking plug is in the correct condition:
     (c) For the PRV 6774B02, 6774B03, 6714D01-D06, 6714D07, 6774E and 6774F:
   (4) Do an Operational Test of the Bleed Air System AMM 36-11-00-710-003
Subtask 36-11-00-810-790-A ** ON A/C NOT FOR ALL
C. During the next five flights, make sure that the fault does not occur again.
   (1) If the fault continues:
   (2) If the fault continues:
Subtask 36-11-00-810-789-C ** ON A/C NOT FOR ALL
D. If the fault continues:
   (1) Do the pressure regulator test of the pressure regulator valve AMM 36-11-00-720-810.
   (2) If the pressure value is lower than 42 psi (2.90 bar):
     (a) Do the functional test of the sense line between the pressure regulator valve and the pressure-regulator valve control-solenoid AMM 36-11-00-720-010.
       1 If the test is not OK:
       2 If the test is OK:
   (3) If the pressure value is more than 56 psi (3.86 bar):
     (a) For PRV 6774G with sense line 6 installed:
       1 Do a functional test of the sense line connected between the bleed pressure regulator valve and the duct assy AMM 36-11-00-720-013.
         a If the test is not OK:
         b If the test is OK:
     (b) For the PRV 6774G without sense line 6 installed:
       1 Do a check of the blancking plug of the IPT and RPT.
         a If the blanking plug is damaged, replace it.
         b If the blanking plug is in the correct condition:
     (c) For the PRV 6774B02, 6774B03, 6714D01-D06, 6714D07, 6774E and 6774F:
   (4) Do an Operational Test of the Bleed Air System AMM 36-11-00-710-003
Subtask 36-11-00-810-790-C ** ON A/C NOT FOR ALL
E. During the next five flights, make sure that the fault does not occur again.
   (1) If the fault continues:
   (2) If the fault continues:
[Rev.8 from Aug 2018] 2026.04.04 04:33:52 UTC