W DOC AIRBUS | TSM A320F

Loss of the Communication from CFDIU


TASK 36-11-00-810-A12-A
Loss of the Communication from CFDIU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 36-11-00-740-802
BITE Test of the Engine Bleed Air System (EBAS) (System Test)
ASM 361103
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-740-106-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the EBAS AMM 36-11-00-740-802.
4. Fault Isolation
Subtask 36-11-00-810-428-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
NO DATA FROM CFDIU
   (1) Replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
Subtask 36-11-00-810-429-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do a check of the wiring from CFDIU (1TW) pin AA/11F and pin AA/11G to the BMC1 (1HA1) pin AA/10C and pin AA/10D ASM 361103.
     (a) If the wiring is damaged:
  • Repair or replace the wiring .
   (2) Do the test given in Para. 3.
Subtask 36-11-00-810-430-A ** ON A/C NOT FOR ALL
C. If the fault continues:
(1) Replace the BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
   (1) Do the test given in Para. 3.
Subtask 36-11-00-810-431-A ** ON A/C NOT FOR ALL
D. If the fault continues:
   (1) Do a check of the wiring from BMC1 (1HA1) pin AB/11D and pin AB/11E to BMC2 (1HA2)pin AA/10C and pin AA/10D ASM 361103.
     (a) If the wiring is damaged:
  • Repair or replace the wiring .
   (2) Do the test given in Para. 3.
Subtask 36-11-00-810-474-A ** ON A/C NOT FOR ALL
E. If the fault continues:
   (1) Replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
[Rev.8 from Aug 2018] 2026.04.04 04:33:55 UTC