W DOC AIRBUS | TSM A320F

Engine 2 Pylon Loop B Inoperative


TASK 36-11-00-810-A03-A
Engine 2 Pylon Loop B Inoperative


1. Possible Causes
  • BMC-2 [1HA2]
  • wiring
  • sensing element
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-803
Bite Test of the BMC
AMM 36-11-52-000-802
Removal of the Bleed Pressure-Regulator Valve
AMM 36-11-52-400-802
Installation of the Bleed Pressure-Regulator Valve
ASM 362202
3. Fault Confirmation
Subtask 36-11-00-740-103-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do a Bite test of the BMC2 AMM 36-11-00-740-803.
4. Fault Isolation
Subtask 36-11-00-810-410-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ENG2 PYLON LOOP B INOP:
NOTE: This procedure is related to the loss of the Pylon-loop B detection signal or to incorrect continuity of the loop.
   (1) If there is continuity:
  • Do a check for a ground signal at pin AC/1 of the BMC2.
     (a) If there is no ground signal:
     (b) If there is a ground signal:
       1 If the fault continues:
  • Do a check and clean all the connections to remove contamination and decrease the resistance of the loop ASM 362202.
   (2) If there is no continuity:
  • Do a check of the wiring from pin AA/4D of the BMC2 to the cable (102HF2) and from pin AA/5D of the BMC2 to the cable (103HF2) ASM 362202.
     (a) If there is no continuity:
     (b) If there is continuity:
  • Do a visual inspection of the sensing elements on the RH Pylon loop B.
       1 If a sensing element is damaged:
       2 If no sensing element is damaged:
  • Do a continuity check of each sensing element, one after the other.
         a If there is no continuity on a sensing element:
         b If there is continuity on a sensing element:
  • Do a check and repair the wiring from the connector AA/4D to the sensing element (101HF2) ASM 362202.
  • Do a check and repair the wiring from the sensing element (106HF2) to the connector AA/5D ASM 362202.
  • Install the BMC-2 [1HA2] AMM 36-11-52-400-802.
   (3) Do the test given in Para. 3.