W DOC AIRBUS | TSM A320F

Engine 2 Bleed-Manifold Pressure Sensor Measurement Failure


TASK 36-11-00-810-A01-A
Engine 2 Bleed-Manifold Pressure Sensor Measurement Failure


1. Possible Causes
  • XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 361102
AMM 36-11-15-000-802
Removal of the Bleed Transferred Pressure-Transducer
AMM 36-11-15-400-802
Installation of the Bleed Transferred Pressure-Transducer
AMM 36-11-15-720-802
Functional Test of the Bleed Transferred Pressure-Transducer with the Bleed Test Set P/N 98D36109001000
3. Fault Confirmation
Subtask 36-11-00-740-101-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not Applicable
4. Fault Isolation
Subtask 36-11-00-810-406-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message TRANSF-PRESS XDCR (7HA2)/WRG:
   (1) Do the functional test of the XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2] AMM 36-11-15-720-802
   (2) If the test is not OK:
Subtask 36-11-00-810-407-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do a check of the wiring from Bleed Manifold Pressure Sensor (7HA2) pin A/1 to BMC2 (1HA2) pin AB/14F ASM 361102.
     (a) If the wiring is damaged:
       1 Repair or replace the wiring .
   (2) Do a check of the wiring from Bleed Manifold Pressure Sensor (7HA2) pin A/3 and pin A/4 to BMC2 (1HA2) pin AA/2D and pin AA/1D ASM 361102.
     (a) If the wiring is damaged:
       1 Repair or replace the wiring .
   (3) Do a check of the wiring from Bleed Manifold Pressure Sensor (7HA2) pin A/3 and pin A/4 to BMC1 (1HA1) pin AA/1H and pin AA/2H ASM 361102.
     (a) If the wiring is damaged:
       1 Repair or replace the wiring .
   (4) After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:33:54 UTC