Bleed Pressure Sensor of Engine 1 Failed


TASK 36-11-00-810-999-A
Bleed Pressure Sensor of Engine 1 Failed


1. Possible Causes
  • XDCR-BLEED REGULATED PRESS, ENG 1 [8HA1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 361101
ASM 361102
AMM 36-11-16-000-802
Removal of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-400-802
Installation of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-720-802
Functional Test of the Bleed Regulated Pressure-Transducer with the Bleed Test Set P/N 98D36109001000
3. Fault Confirmation
Subtask 36-11-00-740-099-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not Applicable
4. Fault Isolation
Subtask 36-11-00-810-402-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message REG-PRESS XDCR (8HA1):
   (1) Do the functional test of the XDCR-BLEED REGULATED PRESS, ENG 1 [8HA1] AMM 36-11-16-720-802
   (2) If the test is not OK:
Subtask 36-11-00-810-403-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do a check of the wiring from Bleed Pressure Sensor (8HA1) pin A/3 and pin A/4 to BMC1 (1HA1) pin AA/2E and pin AA/1E ASM 361101.
     (a) If the wiring is damaged:
       1 Repair or replace the wiring .
Subtask 36-11-00-810-507-A ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) Do a check of the wiring from Bleed Pressure Sensor (8HA1) pin A/3 and pin A/4 to BMC2 (1HA2) pin AA/2F and pin AA/1F ASM 361102.
     (a) If the wiring is damaged:
       1 Repair or replace the wiring .
   (2) After the subsequent flight, make sure that the fault does not continue.