APU By-pass Relay 2 Failed


TASK 36-11-00-810-993-A
APU By-pass Relay 2 Failed


1. Possible Causes
  • RELAY-APU BLEED VALVE CTL
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 204650
3. Fault Confirmation
Subtask 36-11-00-740-093-A ** ON A/C NOT FOR ALL
A. Not applicable
4. Fault Isolation
Subtask 36-11-00-810-379-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message RELAY-APUBV CMND (22HV):
   (1) Replace the RELAY-APU BLEED VALVE CTL ESPM 204650.
Subtask 36-11-00-810-380-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do a check of the wiring between the BMC1 (1HA1) pin AA/15G and BMC2 (1HA2) pin AA/15G and the relay (22HV) pin A/3 connector.
     (a) If the wiring is damaged:
  • Repair or replace the wiring .
Subtask 36-11-00-810-678-A ** ON A/C NOT FOR ALL
C. After the subsequent flight, make sure that the fault does not continue.