W DOC AIRBUS | TSM A320F

CrossBleed Valve Failed


TASK 36-11-00-810-991-A
CrossBleed Valve Failed


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-802
BITE Test of the Engine Bleed Air System (EBAS) (System Test)
AMM 36-11-00-740-803
Bite Test of the BMC
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
AMM 36-12-52-000-001
Removal of the Crossbleed Valve
AMM 36-12-52-400-001
Installation of the Crossbleed Valve
3. Fault Confirmation
Subtask 36-11-00-740-092-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the EBAS AMM 36-11-00-740-802.
4. Fault Isolation
Subtask 36-11-00-810-378-A ** ON A/C NOT FOR ALL
A. If the fault is identified by the fault message XBLEED VALVE (6HV)/CKT:
   (1) Replace the CROSSBLEED VALVE [6HV] AMM 36-12-52-000-001 and AMM 36-12-52-400-001.
     (a) Do the test given in Para. 3.
Subtask 36-11-00-810-387-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Set the XBLEED VALVE SELECTOR SWITCH (3HV) to the CLOSE position:
     (a) If the XBLEED VALVE (6HV) closes:
       1 Remove the BMC1 AMM 36-11-34-000-001.
   (2) Do the test given in Para. 3.
Subtask 36-11-00-810-388-A ** ON A/C NOT FOR ALL
C. If the test is OK:
   (1) Replace the BMC-1 [1HA1] AMM 36-11-34-400-001.
   (2) If the test is not OK:
     (a) Install the BMC1 AMM 36-11-34-400-001.
     (b) Remove the BMC2 AMM 36-11-34-000-001.
     (c) Do the Bite test of the BMC2 (1HA2) AMM 36-11-00-740-803.
Subtask 36-11-00-810-389-A ** ON A/C NOT FOR ALL
D. If the test is OK:
   (1) Replace the BMC-2 [1HA2] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
[Rev.8 from Aug 2018] 2026.04.04 04:33:54 UTC