Bleed Pressure Sensor of Engine 2 Failed


TASK 36-11-00-810-984-A
Bleed Pressure Sensor of Engine 2 Failed


1. Possible Causes
  • XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 361102
AMM 36-11-16-000-802
Removal of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-400-802
Installation of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-720-802
Functional Test of the Bleed Regulated Pressure-Transducer with the Bleed Test Set P/N 98D36109001000
3. Fault Confirmation
Subtask 36-11-00-710-454-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not Applicable
4. Fault Isolation
Subtask 36-11-00-810-360-A ** ON A/C NOT FOR ALL
A. If the fault symptom is idenfied by the maintenance message REG-PRESS XDRC (8HA2):
   (1) Do the functional test of the XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2] AMM 36-11-16-720-802
   (2) If the test is not OK:
Subtask 36-11-00-810-361-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Do a check of the wiring from the Bleed Pressure Sensor (8HA2) pin A/3 and A/4 to BMC2 (1HA2) pin AA/2E and AA/1E ASM 361102.
   (2) If the wiring is damaged:
     (a) Repair or replace the wiring .
Subtask 36-11-00-810-362-A ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) Do a check of the wiring from the Bleed Pressure Sensor (8HA2) pin A/3 and A/4 to BMC1 (1HA1) pin AA/2F and AA/1F ASM 361102.
   (2) If the wiring is damaged:
     (a) Repair or replace the wiring .
Subtask 36-11-00-710-455-A ** ON A/C NOT FOR ALL
D. Test
   (1) After the subsequent flight, make sure that the fault does not continue.