W DOC AIRBUS | TSM A320F

Failure of the Bleed Pressure Sensor of Engine 2


TASK 36-11-00-810-983-A
Failure of the Bleed Pressure Sensor of Engine 2


1. Possible Causes
  • XDCR-BLEED REGULATED PRESS, ENG 2 [8HA2]
  • sense line
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-16-000-802
Removal of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-400-802
Installation of the Bleed Regulated Pressure-Transducer
AMM 36-11-16-720-802
Functional Test of the Bleed Regulated Pressure-Transducer with the Bleed Test Set P/N 98D36109001000
AMM 36-11-49-000-823
Removal of the Environmental Control System (ECS) Sense Lines
AMM 36-11-49-000-832
Removal of the Sense Lines of the Bleed Regulated Pressure-Transducer and the Bleed Transferred Pressure-Transducer
AMM 36-11-49-400-823
Installation of the Environmental Control System (ECS) Sense Lines
AMM 36-11-49-400-832
Installation of the Sense Lines of the Bleed Regulated Pressure-Transducer and the Bleed Transferred Pressure-Transducer
AMM 36-22-00-790-802
Leak Check on all the Bleed Air Ducts and Packs Components
3. Fault Confirmation
Subtask 36-11-00-710-452-A ** ON A/C NOT FOR ALL
A. Not applicable
4. Fault Isolation
Subtask 36-11-00-810-357-A ** ON A/C NOT FOR ALL
A. If the fault symptom is idenfied by the maintenance message REG-PRESS XDRC (8HA2)/SENSE LINE:
   (1) Do the functional test of the bleed regulated pressure-transducer AMM 36-11-16-720-802.
   (2) If the test is not OK:
Subtask 36-11-00-810-359-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Replace the sense line of the bleed regulated pressure-transducer AMM 36-11-49-000-823 AMM 36-11-49-400-823 and AMM 36-11-49-000-832 AMM 36-11-49-400-832.
   (2) Do a leak check of the sense line AMM 36-22-00-790-802.
Subtask 36-11-00-710-453-A ** ON A/C NOT FOR ALL
C. Test
   (1) After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:33:52 UTC