Fault Fuselage Loop Pin Programming
TASK 36-11-00-810-977-A
Fault Fuselage Loop Pin Programming
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-740-116-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-475-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:52 UTC
Fault Fuselage Loop Pin Programming
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| AMM 36-11-34-000-001 | Removal of the BMC |
| AMM 36-11-34-400-001 | Installation of the BMC |
Subtask 36-11-00-740-116-A ** ON A/C NOT FOR ALL
A. Do the BITE test of the BMC1(2) AMM 36-11-00-740-001.
(1) If the test gives the maintenance message WRG: FUSELAGE LOOP PIN PROG, go to Para. Fault Isolation.
4. Fault Isolation(1) If the test gives the maintenance message WRG: FUSELAGE LOOP PIN PROG, go to Para. Fault Isolation.
Subtask 36-11-00-810-475-A ** ON A/C NOT FOR ALL
A. Do a check of the BMC Pin Programming of pin AB/10A:
(1) Make sure that for BMC1 (1HA1) and BMC2 (1HA2) the pin AB/10A is set to open contact.
(2) If the fault continues:
(1) Make sure that for BMC1 (1HA1) and BMC2 (1HA2) the pin AB/10A is set to open contact.
(2) If the fault continues:
- Replace the BMC-1 [1HA1] AMM 36-11-34-000-001 and AMM 36-11-34-400-001.
- Do the test given in Para. 3.