Failure of the HPV of Engine 2 in the Open Position
TASK 36-11-00-810-976-A
Failure of the HPV of Engine 2 in the Open Position
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-440-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-341-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:52 UTC
Failure of the HPV of Engine 2 in the Open Position
1. Possible Causes
[4000HA] - sense line
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-49-000-823 | Removal of the Environmental Control System (ECS) Sense Lines |
| AMM 36-11-49-400-823 | Installation of the Environmental Control System (ECS) Sense Lines |
| AMM 36-11-51-000-802 | Removal of the HP Bleed Valve |
| AMM 36-11-51-400-802 | Installation of the HP Bleed Valve |
| AMM 36-11-51-720-804 | Functional Test of the HP Bleed Valve with the Test Set P/N 98D36109001000 |
| AMM 36-22-00-790-802 | Leak Check on all the Bleed Air Ducts and Packs Components |
Subtask 36-11-00-710-440-A ** ON A/C NOT FOR ALL
A. Not applicable
4. Fault IsolationSubtask 36-11-00-810-341-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message HP BLEED-V (4000HA2)/SENSE LINE:
(1) Turn the manual shaft of the HPV to OPEN.
(2) Let the manual shaft go back to closed position.
(a) If the valve does not go back to the closed position:
Subtask 36-11-00-810-342-A ** ON A/C NOT FOR ALL (1) Turn the manual shaft of the HPV to OPEN.
(2) Let the manual shaft go back to closed position.
(a) If the valve does not go back to the closed position:
- Replace the
[4000HA] AMM 36-11-51-000-802 and AMM 36-11-51-400-802.
- Do a functional test of the opening of the HPV AMM 36-11-51-720-804.
- Replace the
[4000HA] AMM 36-11-51-000-802 and AMM 36-11-51-400-802.
- Continue the trouble shooting procedure.
B. If the fault continues:
(1) Replace the sense line of the HPV AMM 36-11-49-000-823 AMM 36-11-49-400-823.
(2) Do a leak check of the sense line of the HPV AMM 36-22-00-790-802.
Subtask 36-11-00-710-441-A ** ON A/C NOT FOR ALL (1) Replace the sense line of the HPV AMM 36-11-49-000-823 AMM 36-11-49-400-823.
(2) Do a leak check of the sense line of the HPV AMM 36-22-00-790-802.
C. After the subsequent flight, make sure that the fault does not continue.