Failure of Regulation of the Bleed-Pressure Regulating Valve during Take-Off on Engine 1
TASK 36-11-00-810-972-A
Failure of Regulation of the Bleed-Pressure Regulating Valve during Take-Off on Engine 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-433-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-322-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:51 UTC
Failure of Regulation of the Bleed-Pressure Regulating Valve during Take-Off on Engine 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-710-003 | Operational Test of the Bleed Air System |
| AMM 36-11-00-720-010 | Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid with the Bleed Test Set P/N 99127B03 |
| AMM 36-11-00-720-013 | Functional Test of the Sense Line Connected between the Bleed-Pressure Regulator Valve and the Duct Assy with the Bleed Test Set P/N 99127B03 |
| AMM 36-11-00-720-810 | Pressure Regulating Test after Overpressure at Take Off Events with Bleed Test Set P/N 98L36103002000 |
| AMM 36-11-49-000-027 | Removal of the Sense Line between the Pylon Interface and the Duct Assy |
| AMM 36-11-49-000-028 | Removal of the Sense Line between the Pylon Interface and the Duct Assy |
| AMM 36-11-49-000-820 | Removal of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-400-027 | Installation of the Sense Line between the Pylon Interface and the Duct Assy |
| AMM 36-11-49-400-028 | Installation of the Sense Line between the Pylon Interface and the Duct Assy |
| AMM 36-11-49-400-820 | Installation of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-51-000-040 | Removal of the High Pressure Bleed Valve |
| AMM 36-11-51-000-042 | Removal of the High Pressure Bleed Valve |
| AMM 36-11-51-400-040 | Installation of the High Pressure Bleed Valve |
| AMM 36-11-51-400-042 | Installation of the High Pressure Bleed Valve |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-000-042 | Removal of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-042 | Installation of the Bleed Pressure Regulator Valve |
| AMM 36-11-53-000-001 | Removal of the Overpressure Valve |
| AMM 36-11-53-400-001 | Installation of the Overpressure Valve |
| AMM 36-11-53-720-001 | Functional Test of the Overpressure Valves with the Bleed Test Set P/N 98D36003000000 |
Subtask 36-11-00-710-433-A ** ON A/C NOT FOR ALL
A. Only do this trouble shooting procedure if is shown the warning message AIR ENG 1 BLEED FAULT and no maintenance message associated is shown.
4. Fault IsolationSubtask 36-11-00-810-322-A ** ON A/C NOT FOR ALL
A. Functional test
(a) If the test is not OK:
1 Replace the VALVE-OVERPRESSURE, ENG 1 [5HA1] AMM 36-11-53-000-001 and AMM 36-11-53-400-001.
(b) If the test is OK:
1 Continue the troubleshooting procedure.
Subtask 36-11-00-810-328-A ** ON A/C NOT FOR ALL NOTE: The Overpressure Valve (5HA1) is tested in order to verify its correct operation after an overpressure at take-off event.
(1) Do the functional test of the Overpressure Valve (5HA1) AMM 36-11-53-720-001(a) If the test is not OK:
1 Replace the VALVE-OVERPRESSURE, ENG 1 [5HA1] AMM 36-11-53-000-001 and AMM 36-11-53-400-001.
(b) If the test is OK:
1 Continue the troubleshooting procedure.
B. If the fault continues:
(1) Do the pressure regulating test of the Bleed Pressure Regulator Valve (4001HA) AMM 36-11-00-720-810.
(2) If the reference pressure is lower than 42 psig (2.90 bar):
(a) Do the Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid AMM 36-11-00-720-010.
1 If the test is not OK:
(a) For PRV 6774G with sense line 6 installed:
1 Do a functional test of the sense line connected between the bleed pressure regulator valve and the duct assy AMM 36-11-00-720-013.
a If the test is not OK:
1 Do a check of the blancking plug of the IPT and RPT.
a If the blanking plug is damaged, replace it.
b If the blanking plug is in the correct condition:
Subtask 36-11-00-810-329-A ** ON A/C NOT FOR ALL (1) Do the pressure regulating test of the Bleed Pressure Regulator Valve (4001HA) AMM 36-11-00-720-810.
(2) If the reference pressure is lower than 42 psig (2.90 bar):
(a) Do the Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid AMM 36-11-00-720-010.
1 If the test is not OK:
- Repair the sense line for leakage AMM 36-11-49-000-027 and AMM 36-11-49-400-027.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
(a) For PRV 6774G with sense line 6 installed:
1 Do a functional test of the sense line connected between the bleed pressure regulator valve and the duct assy AMM 36-11-00-720-013.
a If the test is not OK:
- Repair the sense line for leakage AMM 36-11-49-000-027 and AMM 36-11-49-400-027.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
1 Do a check of the blancking plug of the IPT and RPT.
a If the blanking plug is damaged, replace it.
b If the blanking plug is in the correct condition:
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
C. During the five subsequent flights check that the failure does not occur again.
(1) If the fault does not occur again, the failure has been correctly solved with the Test defined.
(2) If the fault continues:
Subtask 36-11-00-810-328-C ** ON A/C NOT FOR ALL (1) If the fault does not occur again, the failure has been correctly solved with the Test defined.
(2) If the fault continues:
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- Replace the VALVE-HP BLEED [4000HA] AMM 36-11-51-000-040 and AMM 36-11-51-400-040.
D. If the fault continues:
(1) Do the pressure regulating test of the Bleed Pressure Regulator Valve (4001HA) AMM 36-11-00-720-810.
(2) If the reference pressure is lower than 42 psig (2.90 bar):
(a) Do the Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid AMM 36-11-00-720-010.
1 If the test is not OK:
(a) For PRV 6774G with sense line 6 installed:
1 Do a functional test of the sense line connected between the bleed pressureregulator valve and the duct assy AMM 36-11-00-720-013.
a If the test is not OK:
1 Do a check of the blanking plug of the IPT and RPT:
a If the blanking plug is damaged, replace it.
b If the blanking plug is in the correct condition:
Subtask 36-11-00-810-329-C ** ON A/C NOT FOR ALL (1) Do the pressure regulating test of the Bleed Pressure Regulator Valve (4001HA) AMM 36-11-00-720-810.
(2) If the reference pressure is lower than 42 psig (2.90 bar):
(a) Do the Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid AMM 36-11-00-720-010.
1 If the test is not OK:
- Repair the sense line for leakage AMM 36-11-49-000-820 and AMM 36-11-49-400-820.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
(a) For PRV 6774G with sense line 6 installed:
1 Do a functional test of the sense line connected between the bleed pressureregulator valve and the duct assy AMM 36-11-00-720-013.
a If the test is not OK:
- Repair the sense line for leakage AMM 36-11-49-000-028 and AMM 36-11-49-400-028.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
1 Do a check of the blanking plug of the IPT and RPT:
a If the blanking plug is damaged, replace it.
b If the blanking plug is in the correct condition:
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
E. During the five subsequent flights check that the failure does not occur again.
(1) If the fault does not occur again, the failure has been correctly solved with the Test defined.
(2) If the fault continues:
(1) If the fault does not occur again, the failure has been correctly solved with the Test defined.
(2) If the fault continues:
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Replace the VALVE-HP BLEED [4000HA] AMM 36-11-51-000-042 and AMM 36-11-51-400-042.