Discrete Signal Failure of the BMC2


TASK 36-11-00-810-962-A
Discrete Signal Failure of the BMC2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-710-414-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC2 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-257-A ** ON A/C NOT FOR ALL
A. If the test gives one of the following maintenance message:
BMC2 OR APU FAULT AND 5HV or
BMC2 OR XFEED-V DISCRETE or
BMC2 OR APU BLEED DISCRETE or
BMC2 OR WAI DISCRETE
Subtask 36-11-00-710-415-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.