W DOC AIRBUS | TSM A320F

Spurious ENG BLEED fault indication on the Engine 1


TASK 36-11-00-810-957-A
Spurious ENG BLEED fault indication on the Engine 1


1. Possible Causes
  • BMC-1 [1HA1]
  • P/BSW-ENG 1 BLEED [4HA1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361101
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-740-069-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC1 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-251-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message:
BMC1 OR BLEED FAULT IND 4HA1
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring ASM 361101 between:
    . pin A/C2 of the engine 1 bleed pushbutton switch (4HA1) and pin AA/4A of the BMC1 (1HA1)
    . pin A/C2 of the engine 1 bleed pushbutton switch and pin AA/4A of the BMC1
    . pin A/C3 and the ground.
Subtask 36-11-00-810-251-D ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message:
BMC1 OR BLEED FAULT IND 4HA1
NOTE: If the maintenance message BMC1 OR BLEED FAULT IND 4HA1 comes into view with no associated ECAM warning, no trouble shooting procedure is necessary.
   (1) If the fault continues:
     (a) If the fault continues:
  • Do a check and repair the wiring ASM 361101 between:
    . Pin A/C2 of the engine 1 bleed pushbutton switch (4HA1) and pin AA/4A of the BMC1 (1HA1)
    . Pin A/C2 of the engine 1 bleed pushbutton switch and pin AA/4A of the BMC1
    . Pin A/C3 and the ground.
Subtask 36-11-00-740-070-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:51 UTC