HP Bleed Valve blocked in the closed position or regulation too low on Engine 1 without associated maintenance message
TASK 36-11-00-810-936-A
HP Bleed Valve blocked in the closed position or regulation too low on Engine 1 without associated maintenance message
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-380-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-810-224-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:50 UTC
HP Bleed Valve blocked in the closed position or regulation too low on Engine 1 without associated maintenance message
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 36-11-00-810-837-A | Failure of the HP Bleed Valve of the Engine 1 Blocked in the Closed Position |
Subtask 36-11-00-710-380-A ** ON A/C NOT FOR ALL
A. Do the Last Leg Report Test of the BMC 1
4. Fault IsolationSubtask 36-11-00-810-224-A ** ON A/C NOT FOR ALL
A. If the Last Leg Report Test of the BMC 1 shows the maintenance message:
36-11-51
HP BLEED-V 4000HA1
OR SENSE LINE
36-11-51
HP BLEED-V 4000HA1
OR SENSE LINE
- do the following trouble shooting procedure (Ref. TSM TASK 36-11-00-810-837)