W DOC AIRBUS | TSM A320F

Internal Failure of the BMC2


TASK 36-11-00-810-913-A
Internal Failure of the BMC2


1. Possible Causes
  • BMC-2 [1HA2]
  • XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2]
  • SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361102
AMM 36-11-15-000-001
Removal of the Bleed Transferred Pressure-Transducer
AMM 36-11-15-400-001
Installation of the Bleed Transferred Pressure-Transducer
AMM 36-11-17-000-001
Removal of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-17-400-001
Installation of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-710-272-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the BMC2 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-163-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
CHECK BMC2
   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check for 28VDC at pins 1 and 2 of the bleed transferred pressure transducer (7HA2).
         a If there is no 28VDC:
  • do a check and repair the wiring ASM 361102 between pin 1 of the bleed transferred pressure transducer (7HA2) and the first terminal block.
         b If there is 28VDC:
  • do a check and repair the wiring ASM 361102 between:
    . pin 3 of the bleed transferred pressure transducer (7HA2) and pin AA/15B of the BMC2 (1HA2)
    . pin 4 of the bleed transferred pressure transducer (7HA2) and pin AA/14B of the BMC2
    . pin 4 of the exchanger out temperature sensor (6HA2) and pin AA/10B of the BMC2
    . pin 2 of the exchanger out temperature sensor (6HA2) and pin AA/9B of the BMC2.
Subtask 36-11-00-810-163-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
CHECK BMC2 (1HA2)
   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check for 28VDC at pins 1 and 2 of the bleed transferred pressure transducer (7HA2).
         a If there is no 28VDC:
  • do a check and repair the wiring ASM 361102 between pin 1 of the bleed transferred pressure transducer (7HA2) and the first terminal block.
         b If there is 28VDC:
  • do a check and repair the wiring ASM 361102 between:
    . pin 3 of the bleed transferred pressure transducer (7HA2) and pin AA/15B of the BMC2 (1HA2)
    . pin 4 of the bleed transferred pressure transducer (7HA2) and pin AA/14B of the BMC2
    . pin 4 of the exchanger out temperature sensor (6HA2) and pin AA/10B of the BMC2
    . pin 2 of the exchanger out temperature sensor (6HA2) and pin AA/9B of the BMC2.
Subtask 36-11-00-710-273-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:49 UTC