W DOC AIRBUS | TSM A320F

Internal Failure of the BMC1


TASK 36-11-00-810-912-A
Internal Failure of the BMC1


1. Possible Causes
  • BMC-1 [1HA1]
  • XDCR-BLEED TRANSFER PRESS, ENG 1 [7HA1]
  • SENSOR-EXCHANGER OUT TEMP, ENG 1 [6HA1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361101
AMM 36-11-15-000-001
Removal of the Bleed Transferred Pressure-Transducer
AMM 36-11-15-400-001
Installation of the Bleed Transferred Pressure-Transducer
AMM 36-11-17-000-001
Removal of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-17-400-001
Installation of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-710-270-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the BMC1 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-162-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
CHECK BMC1
   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check for 28VDC at pins 1 and 2 of the bleed transferred pressure transducer (7HA1).
         a If there is no 28VDC:
  • do a check and repair the wiring ASM 361101 between pin 1 of the bleed transferred pressure transducer (7HA1) and the first terminal block.
         b If there is 28VDC:
  • do a check and repair the wiring ASM 361101 between:
    . pin 3 of the bleed transferred pressure transducer (7HA1) and pin AA/15B of the BMC1 (1HA1)
    . pin 4 of the bleed transferred pressure transducer (7HA1) and pin AA/14B of the BMC1
    . pin 4 of the exchanger out temperature sensor (6HA1) and pin AA/10B of the BMC1
    . pin 2 of the exchanger out temperature sensor (6HA1) and pin AA/9B of the BMC1.
Subtask 36-11-00-810-162-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
CHECK BMC1 (1HA1)
   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check for 28VDC at pins 1 and 2 of the bleed transferred pressure transducer (7HA1).
         a If there is no 28VDC:
  • do a check and repair the wiring ASM 361101 between pin 1 of the bleed transferred pressure transducer (7HA1) and the first terminal block.
         b If there is 28VDC:
  • do a check and repair the wiring ASM 361101 between:
    . pin 3 of the bleed transferred pressure transducer (7HA1) and pin AA/15B of the BMC1 (1HA1)
    . pin 4 of the bleed transferred pressure transducer (7HA1) and pin AA/14B of the BMC1
    . pin 4 of the exchanger out temperature sensor (6HA1) and pin AA/10B of the BMC1
    . pin 2 of the exchanger out temperature sensor (6HA1) and pin AA/9B of the BMC1.
Subtask 36-11-00-710-271-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:49 UTC