The Bleed Pressure-Regulator Valve of the Engine 2 is Shown Open Amber on the Lower ECAM DU
TASK 36-11-00-810-907-A
The Bleed Pressure-Regulator Valve of the Engine 2 is Shown Open Amber on the Lower ECAM DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-260-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-810-157-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:49 UTC
The Bleed Pressure-Regulator Valve of the Engine 2 is Shown Open Amber on the Lower ECAM DU
1. Possible Causes
- VALVE-BLEED PRESS REG [4001HA]
- SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2]
- XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| ASM 361102 | |
| AMM 36-11-15-000-001 | Removal of the Bleed Transferred Pressure-Transducer |
| AMM 36-11-15-400-001 | Installation of the Bleed Transferred Pressure-Transducer |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-000-042 | Removal of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-042 | Installation of the Bleed Pressure Regulator Valve |
| AMM 36-11-55-000-001 | Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-55-400-001 | Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid |
Subtask 36-11-00-710-260-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 36-11-00-810-157-A ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message:
Subtask 36-11-00-810-157-D ** ON A/C NOT FOR ALL - do the trouble shooting procedure related to the maintenance message.
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- replace the XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2] AMM 36-11-15-000-001 and AMM 36-11-15-400-001.
- do a check and repair the wiring :
. from the FULLY CLOSED signal of the BMC2 (1HA2) to the bleed pressure-regulator valve (4001HA)
. from pin A/3 of the bleed pressure-regulator valve (4001HA) to the first terminal block ASM 361102.
A. If the test gives a maintenance message:
Subtask 36-11-00-710-261-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 [10HA2] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Replace the XDCR-BLEED TRANSFER PRESS, ENG 2 [7HA2] AMM 36-11-15-000-001 and AMM 36-11-15-400-001.
- Do a check and repair the wiring :
. From pin AA/2B of the BMC2 (1HA2) to pin A/5 of the bleed pressure-regulator valve (4001HA)
. From pin A/3 of the bleed pressure-regulator valve (4001HA) to the first terminal block ASM 361102.
B. After the subsequent flight, make sure that the fault does not continue.