The Bleed Pressure-Regulator Valve of the Engine 1 is Shown Closed Amber on the Lower ECAM DU
TASK 36-11-00-810-903-A
The Bleed Pressure-Regulator Valve of the Engine 1 is Shown Closed Amber on the Lower ECAM DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 36-11-00-710-252-A ** ON A/C NOT FOR ALL 4. Fault Isolation
[Rev.8 from Aug 2018]
2026.04.04 04:33:49 UTC
The Bleed Pressure-Regulator Valve of the Engine 1 is Shown Closed Amber on the Lower ECAM DU
1. Possible Causes
- XDCR-BLEED TRANSFER PRESS, ENG 1 [7HA1]
- VALVE-BLEED PRESS REG [4001HA]
- SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1]
sense line between the bleed pressure-regulator valve (4001HA) and the control solenoid (10HA1) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 36-11-00-720-007 | Functional Test of the Sense Lines Connected to the Bleed Pressure-Regulator Valve with the Bleed Test Set P/N 98D36003000000 |
| AMM 36-11-00-740-001 | BITE Test of the BMC 1(2) |
| ASM 361101 | |
| AMM 36-11-15-000-001 | Removal of the Bleed Transferred Pressure-Transducer |
| AMM 36-11-15-400-001 | Installation of the Bleed Transferred Pressure-Transducer |
| AMM 36-11-15-720-001 | Functional Test of the Bleed Transferred Pressure-Transducer with the Bleed Test Set P/N 98D36003000000 |
| AMM 36-11-49-000-029 | Removal of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-000-042 | Removal of the Pylon Interface Duct |
| AMM 36-11-49-400-029 | Installation of the Pneumatic Sense Lines in the Pylon |
| AMM 36-11-49-400-042 | Installation of the Pylon Interface Duct |
| AMM 36-11-52-000-040 | Removal of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-000-042 | Removal of the Bleed Pressure Regulator Valve |
| AMM 36-11-52-400-040 | Installation of the Bleed Pressure-Regulator Valve |
| AMM 36-11-52-400-042 | Installation of the Bleed Pressure Regulator Valve |
| AMM 36-11-55-000-001 | Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid |
| AMM 36-11-55-400-001 | Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid |
Subtask 36-11-00-710-252-A ** ON A/C NOT FOR ALL 4. Fault Isolation
CAUTION:
BE CAREFUL WITH THE SEMI-FLEXIBLE SENSE LINE. DEFORMATION OF THE RIGID PART OR LARGE DEFORMATION OF THE FLEXIBLE PART CAN QUICKLY CAUSE LEAKAGE.
CAUTION:
USE TWO WRENCHES DURING DISCONNECTION OF THE SENSE LINE, ONE TO MAINTAIN THE FIXED NUT AND THE SECOND ONE TO LOOSEN/TIGHTEN THE SENSE LINE COUPLING.
Subtask 36-11-00-810-153-A ** ON A/C NOT FOR ALL A. If the test gives a maintenance message:
Subtask 36-11-00-810-153-C ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
- do the functional test of the bleed transferred pressure transducer (7HA1) AMM 36-11-15-720-001.
- replace the XDCR-BLEED TRANSFER PRESS, ENG 1 [7HA1] AMM 36-11-15-000-001 AMM 36-11-15-400-001.
- replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-040 and AMM 36-11-52-400-040.
- replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- do the functional test of the upstream sense line between the bleed pressure-regulator valve (4001HA) and the control solenoid (10HA1) AMM 36-11-00-720-007.
* If the pressure decreases to 0 psig in less than 20 seconds:
** replace the relatedsense line between the bleed pressure-regulator valve (4001HA) and the control solenoid (10HA1) AMM 36-11-49-000-029 and AMM 36-11-49-400-029.
* If the pressure drop is not high:
** do a check and repair the wiring :
. from the FULLY CLOSED signal of the BMC1 (1HA1) to the bleed pressure-regulator valve (4001HA)
. from pin A/5 of the bleed pressure-regulator valve (4001HA) to the first terminal block ASM 361101.
A. If the test gives a maintenance message:
Subtask 36-11-00-710-253-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
- Do the functional test of the bleed transferred-pressure transducer (7HA1) AMM 36-11-15-720-001.
- Replace the XDCR-BLEED TRANSFER PRESS, ENG 1 [7HA1] AMM 36-11-15-000-001 and AMM 36-11-15-400-001.
- Replace the VALVE-BLEED PRESS REG [4001HA] AMM 36-11-52-000-042 and AMM 36-11-52-400-042.
- Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 [10HA1] AMM 36-11-55-000-001 and AMM 36-11-55-400-001.
- Do the functional test of the upstream sense line between the bleed pressure-regulator valve (4001HA) and the control solenoid (10HA1) AMM 36-11-00-720-007.
* If the pressure decreases to 0 psig in less than 20 seconds:
* - Replace the relatedsense line between the bleed pressure-regulator valve (4001HA) and the control solenoid (10HA1) AMM 36-11-49-000-042 and AMM 36-11-49-400-042.
* If the pressure decreases by a small value:
* - Do a check and repair the wiring :
. From pin AA/2B of the BMC1 (1HA1) to pin A/5 of the bleed pressure-regulator valve (4001HA)
. From pin A/5 of the bleed pressure-regulator valve (4001HA) to the first terminal block ASM 361101.
B. After the subsequent flight, make sure that the fault does not continue.