W DOC AIRBUS | TSM A320F

Low Bleed Temperature of the Engine 2 in Descent


TASK 36-11-00-810-895-A
Low Bleed Temperature of the Engine 2 in Descent


1. Possible Causes
  • SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2]
  • wiring
  • VALVE-HP BLEED [4000HA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361102
AMM 36-11-17-000-001
Removal of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-17-400-001
Installation of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-51-000-040
Removal of the High Pressure Bleed Valve
AMM 36-11-51-000-042
Removal of the High Pressure Bleed Valve
AMM 36-11-51-400-040
Installation of the High Pressure Bleed Valve
AMM 36-11-51-400-042
Installation of the High Pressure Bleed Valve
3. Fault Confirmation
Subtask 36-11-00-710-237-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC 2 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-145-A ** ON A/C NOT FOR ALL
A. If the BITE test gives no maintenance message:
  • no maintenance is necessary.
   (1) If the BITE test gives the class 3 maintenance message:
TEMP SENSOR 6HA2
     (a) If the fault continues:
  • Do a check and repair the wiring ASM 361102 between:
    . pin 4 of the engine 2 exchanger output temperature sensor (6HA2) and pin AA/10B of the BMC 2 (1HA2)
    . pin 2 of the engine 2 exchanger output temperature sensor and AA/9B of the BMC 2
    . pin 1 and the ground.
   (2) If the BITE test gives the class 3 maintenance message:
HP BLEED-V 4000HA2
Subtask 36-11-00-810-145-B ** ON A/C NOT FOR ALL
A. If the BITE test gives no maintenance message:
  • no maintenance is necessary.
   (1) If the BITE test gives the class 3 maintenance message:
TEMP SENSOR 6HA2
     (a) If the fault continues:
- Do a check and repair the wiring ASM 361102 between:
. pin 4 of the engine 2 exchanger output temperature sensor (6HA2) and pin AA/10B of the BMC 2 (1HA2)
. pin 2 of the engine 2 exchanger output temperature sensor and AA/9B of the BMC 2
. pin 1 and the ground.
   (2) If the BITE test gives the class 3 maintenance message:
HP BLEED-V 4000HA2
Subtask 36-11-00-710-238-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:33:48 UTC