W DOC AIRBUS | TSM A320F

Low Bleed Temperature of the Engine 2 in Climb


TASK 36-11-00-810-893-A
Low Bleed Temperature of the Engine 2 in Climb


1. Possible Causes
  • SENSOR-EXCHANGER OUT TEMP, ENG 2 [6HA2]
  • wiring
  • VALVE-FAN AIR, ENG2 [9HA2]
  • THERMOSTAT-FAN AIR VALVE CTL [7170HM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361102
AMM 36-11-17-000-001
Removal of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-17-400-001
Installation of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-43-000-001
Removal of the Fan-Air Valve Control-Thermostat
AMM 36-11-43-400-001
Installation of the Fan-Air Valve Control-Thermostat
AMM 36-11-54-000-001
Removal of the Fan Air Valve
AMM 36-11-54-400-001
Installation of the Fan Air Valve
3. Fault Confirmation
Subtask 36-11-00-710-233-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC 2 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-143-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the class 3 maintenance message:
TEMP SENSOR 6HA2
   (1) If the fault continues:
  • Do a check of the wiring ASM 361102 between:
    . pin 4 of the engine 2 exchanger output temperature sensor (6HA2) and pin AA/10B of the BMC 2 (1HA2)
    . 2 of the engine 2 exchanger output temperature sensor and pin AA/9B of the BMC 2
    . pin 1 and the ground.
     (a) If the wiring is not correct:
  • Repair the wiring .
     (b) If the wiring is correct:
       1 If the fault continues:
Subtask 36-11-00-710-234-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:33:48 UTC