W DOC AIRBUS | TSM A320F

Loss of the Bleed Temperature Monitoring of the Engine 1


TASK 36-11-00-810-889-A
Loss of the Bleed Temperature Monitoring of the Engine 1


1. Possible Causes
  • SENSOR-EXCHANGER OUT TEMP, ENG 1 [6HA1]
  • BMC-1 [1HA1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
AMM 36-11-17-000-001
Removal of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-17-400-001
Installation of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-34-000-001
Removal of the BMC
AMM 36-11-34-400-001
Installation of the BMC
3. Fault Confirmation
Subtask 36-11-00-710-225-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC1 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-139-A ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (1) If there is no maintenance message:
     (a) If the fault continues:
Subtask 36-11-00-710-226-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:33:48 UTC