Low Bleed Temperature of the Engine 1 in Climb


TASK 36-11-00-810-886-A
Low Bleed Temperature of the Engine 1 in Climb


1. Possible Causes
  • SENSOR-EXCHANGER OUT TEMP, ENG 1 [6HA1]
  • wiring
  • VALVE-FAN AIR, ENG1 [9HA1]
  • THERMOSTAT-FAN AIR VALVE CTL [7170HM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-11-00-740-001
BITE Test of the BMC 1(2)
ASM 361101
AMM 36-11-17-000-001
Removal of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-17-400-001
Installation of the Heat-Exchanger Outlet-Temperature Sensor
AMM 36-11-43-000-001
Removal of the Fan-Air Valve Control-Thermostat
AMM 36-11-43-400-001
Installation of the Fan-Air Valve Control-Thermostat
AMM 36-11-54-000-001
Removal of the Fan Air Valve
AMM 36-11-54-400-001
Installation of the Fan Air Valve
3. Fault Confirmation
Subtask 36-11-00-710-219-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the BMC 1 AMM 36-11-00-740-001.
4. Fault Isolation
Subtask 36-11-00-810-136-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the class 3 maintenance message:
TEMP SENSOR 6HA1
   (1) If the fault continues:
  • Do a check of the wiring ASM 361101 between:
    . pin 4 of the engine 1 exchanger output temperature sensor (6HA1) and pin AA/10B of the BMC 1 (1HA1)
    . pin 2 of the engine 1 exchanger output temperature sensor and pin AA/9B of the BMC 1
    . pin 1 and the ground.
     (a) If the wiring is not correct:
  • Repair the wiring .
     (b) If the wiring is correct:
       1 If the fault continues:
Subtask 36-11-00-710-220-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.